Specifications
84414-01
INPUTS
Signal Inputs:
Signal Scale Factors:
Two channels proximity input, 10 kohm input impedance.
100mV/mil (4.0V/mm) - 11 and 14 mm proximity probes.
20mV/mil (0.8V/mm) - 25 and 35 mm proximity probes.
10mV/mil (0.4V/mm) - 50 mm proximity probe.
SIGNAL CONDITIONING
Monitor Range: F u l l scale meter range selected per Option Table.
Accuracy:
±
0.33% of full scale error typical at 77°F (25°C).
± 1% of full scale error maximum at 77°F (25°C).
ALARMS
Alarm Setpoints:
Alarm Delay:
•
DISPLAYS
Meter:
LEDs:
•
CONTROLS
Front Panel:
Internal:
External:
OUTPUT
Recorder:
Transducer Power:
Alert/Danger alarm levels (adjustable from 0 to 100% of full scale).
Alarm delay times are user-programmable per options.
LCD bargraph, dual scale with outside scales marked per monitor full scale range. Bargraph
resolution is 1.6% of full scale. Center scale marked for probe Gap voltage.
Green LEDs annunciate transducer OK condition, red LEDs annunciate Danger, Alert, and
Bypass conditions.
Front panel switches (3) for reading Alert and Danger setpoint levels, and for reading probe
Gap voltage.
Switches on circuit board for setpoint adjustment, Danger Bypass, Monitor Bypass, and
calibration functions.
External remote controls: Reset, inhibit, and setpoint and calibration adjust (t and t).
Output proportional to selected full scale monitor range and protected against continuous short
circuit to ground:
+4 mA to +20 mA, +12 Vdc compliance.
+1 Vdc to + 5 Vdc, 100 ohm output impedance.
0 Vdc to -10 Vdc, 100 ohm output impedance.
-24 Vdc or -18 Vdc per option selected in power supply. Output is short circuit protected.
Alarms and OK: R e l a y drives for Alert, Danger, and system OK.
3 5
Summary of Contents for 3300/46
Page 11: ...Ramp Differential Expansion Monitor Operation 8 4 4 1 3 0 1 Blank Page i v...
Page 13: ...Ramp Differential Expansion Monitor Operation 8 4 4 1 3 0 1 Blank Page v i...
Page 30: ...3300 46 RAMPDIFFERENTIAL EXPANSION MONITOR MAINTENANCE MANUAL BENTLY r NEVADA PART NO 84414 01...
Page 33: ...Ramp Differential Expansion Monitor Maintenance 84414 01 Blank Page i v...
Page 35: ...Ramp Differential Expansion Monitor Maintenance Blank Page 84414 01 v i...
Page 80: ...i w W2 19 E 1 Ramp Differential Expansion Monitor Schematic Sheet 6 of 11...
Page 82: ...f 99 9 L9 9 9 9 j T Ramp Differential Expansion Monitor Schematic Sheet 8 of 11...