Ramp Differential Expansion Monitor Maintenance
6
Monitor Options [Cont]
84414-01
•
Transducer Type Options
To set the monitor for the correct transducer type, remove all jumpers from headers W21C and D,
W22B-D, W4A-F, and W16 and W17. Install jumpers specified in Table 3.
Table 3. Transducer Type Options *
Transducer Type
Install Jumpers
11 mm, 100mV/mil
14 mm,
100mV/mil
25 mm, 20 mV/mil
35 mm, 20 mV/mil
50 mm, 10 mV/mil
W4A,B,D,E, W16, W17, W21D
W4A,B,D,E, W16, W17, W21D, W22D
W4A,B,D,E, W16, W17, W21D, W22C
W4A,B,D,E, W16, W_17, W21D, W22C,D
W4A,B,D,E, W16, W17, W21D, W22B
Full Scale Range Options
To set the monitor full scale range option, remove jumpers W15A-E. Install jumpers specified in
Table 4.
Table 4. Full Scale Range Options *
Full Scale Range
Install Jumpers
5 - 0 - 5 mm
0 - 10 mm
0.25 - 0 - 0.25 inches
O - 0.5 inches
10 - 0 - 10 mm
0 - 20 mm
0.5 - 0 - 0.5 inches
O - 1.0 inches
1.0 - 0 - 1.0 inches
O - 2.0 inches
25 - 0 - 25 mm
0 - 50 mm
W15A,C
W15A,C,D
W15A,B
W15A,B,D
W15A,B,C
W15A,B,C,D
W15D,E
W15B,C,D,E
W15C,D,E
W15A,E
W15B,E
* Note: Changing the transducer type or full scale range requires recalibration of the monitor.
See section 13.
12
Summary of Contents for 3300/46
Page 11: ...Ramp Differential Expansion Monitor Operation 8 4 4 1 3 0 1 Blank Page i v...
Page 13: ...Ramp Differential Expansion Monitor Operation 8 4 4 1 3 0 1 Blank Page v i...
Page 30: ...3300 46 RAMPDIFFERENTIAL EXPANSION MONITOR MAINTENANCE MANUAL BENTLY r NEVADA PART NO 84414 01...
Page 33: ...Ramp Differential Expansion Monitor Maintenance 84414 01 Blank Page i v...
Page 35: ...Ramp Differential Expansion Monitor Maintenance Blank Page 84414 01 v i...
Page 80: ...i w W2 19 E 1 Ramp Differential Expansion Monitor Schematic Sheet 6 of 11...
Page 82: ...f 99 9 L9 9 9 9 j T Ramp Differential Expansion Monitor Schematic Sheet 8 of 11...