Ramp Differential Expansion Monitor Maintenance
1 13 I C a l i b r a t e Channels [Conti
8. Activate the Channel A gain adjust dip
switch (GA) by moving it to the left. The
Channel A bargraph will begin t o flash.
Measure the voltage at Test point Channel A
(TA) using the multimeter. Adjust the power
supply to the Full Upscale Voltage
(FUSV)
(reference Table 10).
9. Press the
GAP
switch and use the System
Monitor ('1') and (1) switches to adjust the
gain until the Test point Channel A (TA) is at
+5.0 ±0.05 Vdc and the
BYPASS
LED is on
steady (not flashing). The flashing
BYPASS
LED indicates an overrange condition. If this
occurs, reduce the gain using the System
Monitor (1) switch.
10. Deactivate the Channel A gain adjust dip
switch
(GA)
by moving it to the right. If the
short i s removed f r o m t h e calibration
terminals (CA) before t h e d i p switch i s
deactivated, t h e adjustment will n o t b e
stored.
11. Repeat steps 8 through 10 for Channel B
substituting
GB and TB.
84414-01
2 6
90'd E 2 E 6 U O L 'ON XV.] O N I I E N V W 9 9 : E I 6 6 - 8 0 - 0 a 1
Summary of Contents for 3300/46
Page 11: ...Ramp Differential Expansion Monitor Operation 8 4 4 1 3 0 1 Blank Page i v...
Page 13: ...Ramp Differential Expansion Monitor Operation 8 4 4 1 3 0 1 Blank Page v i...
Page 30: ...3300 46 RAMPDIFFERENTIAL EXPANSION MONITOR MAINTENANCE MANUAL BENTLY r NEVADA PART NO 84414 01...
Page 33: ...Ramp Differential Expansion Monitor Maintenance 84414 01 Blank Page i v...
Page 35: ...Ramp Differential Expansion Monitor Maintenance Blank Page 84414 01 v i...
Page 80: ...i w W2 19 E 1 Ramp Differential Expansion Monitor Schematic Sheet 6 of 11...
Page 82: ...f 99 9 L9 9 9 9 j T Ramp Differential Expansion Monitor Schematic Sheet 8 of 11...