Universal Cellular Communicator
SMS Programming
In addition to the processes described in the paragraph “Remote output activation/deactivation” on page 29, it is also possible to
carry out other remote procedures through the transmission of various SMS messages.
Changing the user code
The default user code is 000000; to change it, send an SMS message consisting of the characters #
CUC
followed by the current
user code and the new user code between
*
characters, in accordance with the following formula:
#
CUC
*User code*New user code*
The device will send an SMS to confirm that the user code has changed.
The new user code must be 6 digits long (0-9).
Enabling/disabling remote programming
Remote programming allows you to operate the Console over a network. To set the communicator's parameters remotely, you must
enable remote programming, either with the Console (see “
Network Settings
” on page 43), or with an SMS composed of the
characters #
ERA
followed by the User Code and
ON
enclosed in
*
as follows:
#
ERA
*User code*
ON
*
To disable remote programming, send the following SMS:
#
ERA
*User code*
OFF
*
The device will confirm with an SMS.
Changing the installer code
The 6-digit installer code is used to access the remote programming interface (see “
Installer Authentication
” on page 41). The
default installer code is 111111; to change it, send an SMS message consisting of the characters #
CIC
followed by the current
Installer code and the new Installer code between
*
characters, in accordance with the following formula:
#
CIC
*Installer code*New installer code*
The new installer code must be 6 digits long (0-9).
If the EN50136 option is enabled, the installer must be authorised by the normal user for the installer code change to
take effect.
The device will send an SMS to confirm that the installer code has changed.
Changing the level 4 installer code
The default level 4 installer code is 222222; to change it, send an SMS composed of the characters #
CMC
followed by the current
Level 4 Installer code and the new Level 4 Installer code enclosed between
*
, as follows:
#
CMC
*Level 4 installer code*New level 4 installer code*
The new level 4 installer code must be 6 digits long (0-9).
For the Level 4 installer code change to take effect, the Level 4 installer must be authorised by the installer.
The device will send an SMS to confirm that the level 4 installer code has changed.