220 Series
7
Technical specifications
The power for the communicator is supplied by the panel to which it is connected (10.7 V to 27.6 V) or by an external power supply
which also recharges an optional backup battery, if necessary. The sole purpose of the battery is to supply power in case of failure
of the primary power source (8 hours stand-by).
When the communicator is powered by the battery, ONLY communicator events are transmitted.
The primary power and (optional) battery voltages are supervised.
The power supply for communicator models BGS-220 and B3G-220/EU must be SELV, with power limited to 1 A.
Version
BGS-220K
B3G-220K/EU
BGS-220
B3G-220/EU
Input Voltage
10.7 ÷ 27.6 V
_
Standby average current, without battery
90 mA (not including outputs) @ 13.8 V
_
Average current consumption per hour
100 mA
Maximum current draw in current limited
mode (versions with housing only)
230 mA (not including outputs) @ 13.8 V
_
Maximum current draw
450 mA (not including outputs) @ 13.8 V
_
Outputs
6 open-collector, 100 mA
Operating frequency
See Table 2
Maximum loop resistance of line between
the device connected in series on LI
1 Kohm
Maximum number of parallel devices
connected on LI
1
Environmental class
II
Operating temperature
-10 ÷ +40°C
Humidity
0 ÷ 95%
Dimensions (LxHxD)
76x151x20 mm (PCB only)
101x186x41 mm
Weight
66 g
250 g
Table 1 – Technical specifications.
Version
Operating frequency (MHz)
GSM/GPRS/EDGE
UMTS/HSPA
BGS-220K, BGS-220
850/900/1800/1900
N/A
B3G-220K/EU, B3G-220/EU
900/1800
900/2100
Table 2 – Operating frequency.