220 Series
23
Internal events
Along with the external events (panel events decoded with the Contact ID / SIA protocols on the simulated PSTN line),
the communicator also recognises the following events.
Event
Description
Input 1 Event
This occurs when terminal T1 is programmed as an input and the conditions for its
activation obtain (see “
Inputs/Outputs
” on page 44).
Input 2 Event
Like
Input 1 Event
but for terminal T2.
Input 3 Event
Like
Input 1 Event
but for terminal T3.
Input 4 Event
Like
Input 1 Event
but for terminal T4.
Input 5 Event
Like
Input 1 Event
but for terminal T5.
Input 6 Event
Like
Input 1 Event
but for terminal T6.
Input 1 Restore
This occurs when terminal T1 is programmed as an input, and returns to standby status
(see “
Inputs/Outputs
” on page 44).
Input 2 Restore
Like
Input 1 Restore
but for terminal T2.
Input 3 Restore
Like
Input 1 Restore
but for terminal T3.
Input 4 Restore
Like
Input 1 Restore
but for terminal T4.
Input 5 Restore
Like
Input 1 Restore
but for terminal T5.
Input 6 Restore
Like
Input 1 Restore
but for terminal T6.
Mains Fault
Happens when the power voltage (teV) drops below 10 V.
Mains Fault Restore
Happens when the power voltage (teV) rises above 12 V.
Battery Fault
Happens when the battery voltage falls below 3.4 V.
Battery Restore
Happens when the battery voltage rises above 3.7 V.
Panel Interconnection Fault
Happens when the terminal programmed as the
Panel Interconnection Present
input
is activated (see “
Inputs/Outputs
” on page 44).
Panel Interconnection Restore
Happens when the terminal programmed as the
Panel Interconnection Present
input
is deactivated (see “
Inputs/Outputs
” on page 44).
Cellular Receiver 1 Fault
Happens when the communicator is NOT able to communicate with receiver 1:
initialisation failure, supervision failure or receiver does not respond (see “
IP Receivers
”
on page 49).
Cellular Receiver 2 Fault
Like
Cellular Receiver 1 Fault
but for receiver 2.
Cellular Receiver 1 Restore
Happens when the communicator is able to communicate with receiver 1: initialisation
successful, supervision successful or receiver responds (see “
IP Receivers
” on
page 49).
Cellular Receiver 2 Restore
Like
Cellular Receiver 1 Restore
but for receiver 2.
PSTN Fault
Happens when the voltage on terminals LE is less than 2.5 V for the set
LE Failure
Timeout (sec)
(see “
Timeouts
” on page 51).
PSTN Fault Restore
Happens when the voltage on terminals LE is more than 2.5 V for the set
LE Restore
Timeout (sec)
(see “
Timeouts
” on page 51).
Cellular Network Fault
The communicator can NOT connect to the cellular data network.
Cellular Network Restore
The communicator can connect to the cellular data network.
Tamper Event
Happens when tamper detection is enabled (see “Description of jumpers” on page 8) and
the communicator is opened or removed from the wall (versions with housing only).
Table 10 – Description of events handled by communicator.