n
A, B, C and D Arming (<PIN> A, B, C or D + ON)
+
DO NOT assign Duress PINs to A, B, C or D Mode
Arming commands.
Each user PIN can be set up to manage four different
Arming mode configurations:
A
,
B
,
C
and
D
. These con-
figurations determine the Partitions that will Arm, and
those that will Disarm when an
A
,
B
,
C
or
D
Mode com-
mand+
ON
to confirm the choise, is entered at a Key-
pad, (the final configuration depends on the User PIN
and Keypad Partitions).
+
Keypads can operate ONLY on the Partitions they
are assigned to.
+
You can Arm/Disarm the Partitions separately us-
ing a 6-digit User PIN, as follows: — type in a
6-digit User PIN followed by the 2-digit ID number
of the Partition concerned , then press
ON
,
OFF
,
A
,
B
, as required.
Example
: If the 6-digit User PIN is
135790
, and you want to Arm Partition
13
in Away
Mode, type-in
13579013
then press ON. If you
want to Disarm Partition 13, using the same PIN,
type-in
13579013
then press
OFF
. If you enter
13579013 then press
A
,
B
, Partition 13 will Arm in
accordance with the respective configuration.
n
Notes on Arming from Keypads
Before your system Arms, your Control panel will check
for the following conditions:
Active Detector, Masked Zone, Detector Fault, Tamper,
Interconnection Fault, Mains Fault, Battery Fault, Alarm
Tx Fault, Siren Fault, Bypassed Zone, Inactive zone,
WLS silent zone.
If you are operating from an LCD keypad, these condi-
tions will be signalled in real-time on the display.
If more Bypassed Zones or Inactive zones are present,
the display shows all alternately at intervals of two sec-
onds.
At this point you can do one of the following:
a) Press the
ENTER
key and anyway perform the Arm-
ing request of control panel;
+
In the presence of
Active Detectors
(zones), you
cannot force the arming; it is necessary to remove
the cause.
b) press the
ESC
key to cancel the Arming request.
n
Silencing Alarm Devices
The quickest way to silence Alarm Signalling Devices
(Sirens and Flashers) is to Disarm the system.
+
This operation will not interrupt the ongoing Alarm
call, or end the Alarm call cycle. Therefore, it will be
necessary access the User Menu (access allowed
to Master User PINs only), and stop the Alarm
calls, via the ‘Clear Call Queue’ option.
Tamper events, which occur when the system is dis-
armed, can be silenced via the “Reset Alarm” and “Out-
put ON/OFF” option from the User Menu (access
allowed to Master and User PINs).
For
further
information,
refer
to
“Using
Digital
Keys/Cards”.
n
Wrong PIN
If a wrong PIN is entered, on a
LCD keypad
the display
will show an error message.
May/14/10 10.50
WRONG PIN
After a few seconds the keypad come back in the
“
standby status”
and the right PIN can be entered
again. After 10 wrong entries the LCD keypad will lock
for 90 seconds.
Keyboard Locked
Invalid PINS!
36
Expandable Hybrid Control Panel
ABSOLUTA
Summary of Contents for ABSOLUTA ABS104M50
Page 67: ......