![Bentel Security ABSOLUTA ABS104M50 User Manual Download Page 33](http://html1.mh-extra.com/html/bentel-security/absoluta-abs104m50/absoluta-abs104m50_user-manual_2735349033.webp)
ABSOLUTA
OPERATIONS FROM LCD KEYPAD
33
LEDs
DESCRIPTION
I
OFF
All the keypad Partitions are Disarmed.
ON
At least one of the keypad Partitions is Armed.
Slow Blinking
During the selection of partitions.
a
OFF
NO alarms or Tamper active.
ON
At least one Alarm or Tamper active.
Slow Blinking
All Alarm Partition and Tampers are in memory (restored).
G
OFF
When the Keypad's Partitions are
disarmed
, it signals no info to communicate.
ON
When the Keypad's Partitions are
disarmed
, it signals: Alarms, Tampers, Troubles, Bypassed
Zones, if the Keypad is in
Standby Status
; Troubles, in the
View Partition Status
mode.
When a Keypad's Partitions is
armed
, this LED is disabled.
Slow Blinking
All troubles in memory (restored).
The zone Alarm and Tamper events, signalled on the LEDs, refer to zones which belong to the keypad Partitions.
Table 3
LCD keypad.
INITIAL
MODE
DESCRIPTION
A
Away
The system will turn ON the perimeter and internal zones of the respective Partition.
P
Stay
The system will turn ON the perimeter zones of the respective Partition and will leave
the internal zones OFF.
Z
Stay - 0 Delay
The system will turn ON the perimeter zones of the respective Partition and will leave
the internal zones OFF, and will remove the Entry Time from zones which have one.
D
Disarm
The system will turn OFF the perimeter and internal zones of the respective Partition.
t
Test
At least one zone is in Test status for the relative partition.
*
Alarm Partition
The corresponding partition is in Alarm Status.
!
Alarm Memory
The corresponding partition has an Alarm in memory.
If the partition is selected, the letters will blink.
Table 4
Arming/Disarming Partitions.
ICON
SIGN
DESCRIPTION
S
X
ON
Control panel Tamper (Control panel open or dislodged).
Blinking
Control panel Tamper has cleared but at least one Open Panel event in memory.
T
X
ON
System Tamper.
Blinking
System Tamper has cleared but there is at least one System Tamper event in memory.
b
X
ON
Tamper on at least one peripheral device (Keypad, Reader, Expander or Receive.
Blinking
Peripheral Tamper has cleared but there is at least one Peripheral Tamper event in memory.
f
X
ON
A False Key/Card is present at a Reader.
Blinking
At least one False Key/Card event in memory.
s
X
ON
A peripheral device (Keypad, Reader, Wireless or Expander) has been disconnected.
Blinking
At least one Peripheral Trouble event in memory.
Table 5
Tamper signals.
ICON
SIGN
DESCRIPTION
t
*
p
OFF
Installer Disabled.
ON
Blinking
Installer Enabled.
PIN Transfer Enabled.
r
*
OFF
Answerphone facility Disabled.
ON
Answerphone facility Enabled.
i
ÿ
OFF
Line Free.
ON
Line Busy.
Blinking
Line Down.
Table 6
Telephone signals.
Summary of Contents for ABSOLUTA ABS104M50