4) Current Arming Status
The coloured box shows
current Partition status:
Ø
GREEN with the label
Disarmed
, if
ALL Keypad Partitions are DISARMED;
Ø
RED with the label
Armed Global
, if
ALL Keypad Partitions are ARMED;
Ø
RED with the label
Armed
if AT LEAST
ONE Keypad Partition is ARMED.
5) Arming/disarming key
The grey key arms the Parti-
tions as selected or disarms them:
Ø
GREY with the label
Arm Global
,
ARMS ALL the Partitions of the Keypad and PIN
used;
Ø
GREY with the label
Arm STAY type
A
, ARMS/DISARMS the Partitions of the Keypad and
PIN used in the programmed mode;
+
The label
Arm STAY Type A
Arming depends on
the Arming Mode selected and can be modified by
the installer.
Ø
GREY
with
the
label
Disarm
,
DISARMS ALL the Partitions of the Keypad and PIN
used.
Here below you will find some possible combinations of
the box displaying the current status of Partitions and
the Arming Key:
Ø
ALL Partitions DISARMED and an Arming Mode se-
lected (Global, in the following example):
Ø
Partitions ARMED is a Mode (
Global
, in the following
example) and SAME Arming Mode selected:
Ø
Partitions ARMED in a Mode (
STAY Type A
in the
following example) and DIFFERENT Arming Mode
selected (
Global
, in the following example):
n
Arming
Select the desired Arming Mode then press the Arming
Key:
If there are no Arming Block Conditions (see relative
paragraph), the keypad starts to scan Exit Delay (if pro-
grammed).
+
Exit Delay is also signalled audibly increasing in
frequency when arming is in less than 10 seconds.
Leave the protected zones, along the preset route, be-
fore Exit Delay expires or disarm the Partitions.
At the end of Exit Delay (if programmed), the keypad
displays the Standby Screen.
n
Disarming
If you violate a Delayed Zone, the keypad starts scan-
ning Entry Delay:
In that case, just enter a valid PIN and press
, to dis-
arm the Partitions before Entry Delay expires.
In all other cases, enter the Home Screen as described
in “Entering the Home Screen” and press
Disarm
.
+
Entry Delay is also signalled audibly increasing in
frequency when the alarm will go off in less than 10
seconds.
At the end of the disarming operation, the keypad dis-
plays the Standby Screen.
ABSOLUTA
OPERATIONS FROM TOUCH KEYPAD
11
Summary of Contents for ABSOLUTA ABS104M50
Page 67: ......