28
890053-03-01
Connecting with Other Products
10.2.4 Supported Objects
①
Identity Object (Class 0x01, Instance 1)
Attribute
Attribute
ID
Access
Attribute Name
Data Length
Attribute
Value
1
Get
Vendor ID
Word
259
2
Get
Device Type (inverter)
Word
2
3
Get
Product Code
Word
100 (Note1)
4
Get
Revision
High Byte - Major Revision
Low Byte - Minor Revision
Word
(Note2)
0x0101
5
Get
Status
Word
(Note3)
6
Get
Serial Number
Double Word
(Note4)
7
Get
Product Name
4 Byte
CENT
(Note1) Product Code 100 refers to the Benshaw inverter.
(Note2) The revision number is identical to the version of the EtherNet/IP. The high byte
stands for a major revision number, and the low byte stands for a minor revision
number. For examp
le, “0x0101” stands for "version 1.01."
It is separate from the OS version of the communication option board (displayed on
the Keypad COM-06 FBus S/W Ver).
(Note3) Definition of status bits
Bit
Description
0
0: Device is not connected to the master
1: Device is connected to the master
1
Reserved
2
Configured
(fixed as ‘0’ because EtherNet/IP is not supported)
3
Reserved
4
0: Unknown
2: Faulty IO connection
3: IO connection has not been made
5: Major fault
6: IO connection has been made
5
6
7
8
Minor recoverable fault (Inverter is in warning status)
9
Minor unrecoverable fault (N/A)
10
Major recoverable fault (inverter H/W trip occurred)
11
Major recoverable fault (inverter non-H/W trip occurred)
(Note4) Serial number uses the last 4 digits of the MAC ID.