23
EN
Selection of photocells functioning (PHCL)
It is possible to select the functioning mode of the photocells connected to the PHOT input. Normally, the photocells are active only in the closing phase, to allow the access of the
vehicle even when the gate is not completely open. If this intervention is also desired in the opening phase, modify the parameter as follows:
1
Press the [PGM] button to access programming or if the control unit is already in the programming menu, press [
] until the PHCL
menu is displayed.
PMOT
PHCL
2
Press the [PGM] button to enter the PHCL regulation.
The display shows the current value of the PHCL parameter.
Use the [
] key to select one of these values:
ON
Photocells active in the opening and closing phase
OFF
Photocells only active in the closure phase (default)
on
off
3
Confirm the desired value using the [PGM] key, the display shows PRG.
PRG
4
The control unit goes back to the PHCL menu. To exit programming, press the [PGM] and [
] buttons at the same time or, alternatively,
remove the power supply or wait 60 seconds.
PGM+
Selection of direction of rotation of the motor (MINV)
The sliding gates can open by sliding to the right or to the left, as indicated in Figure.
SX
OPEN
OPEN
DX
The direction of rotation may have to be inverted according to the position of the motor.
1
Press the [PGM] button to access programming or if the control unit is already in the programming menu, press [
] until the MINV
menu is displayed.
PMOT
MINV
2
Press the [PGM] button to enter the MINV regulation.
The display shows the current value of the MINV parameter.
Use the [
] key to select one of these values:
C__O
Motor with opening to the right
O__C
Motor with left opening - default setting-
o--c
c--o
3
Confirm the desired value using the [PGM] key, the display shows PRG.
PRG
4
The control unit goes back to the MINV menu. To exit programming, press the [PGM] and [
] buttons at the same time or, alternatively,
remove the power supply or wait 60 seconds.
PGM+
Energy saving functioning mode (ESA)
With the “ESA” energy saving function activated ,when a full opening or closing cycle is complete the control panel is in a condition of full energetic efficiency ,reducing at the
minimum the energetic consumption by taking off power supply from the transformer and accessories.
1
Press the [PGM] button to access programming or if the control unit is already in the programming menu, press [
] until the ESA
function is displayed.
PMOT
ESA
2
Press the [PGM] button to enter the ESA regulation.
A
The display shows the current value of the ESA parameter.
A
ON
ESA mode activated (default)
A
OFF
ESA mode deactivated
A
on
off
3
Confirm the desired value using the [PGM] key, the display shows PRG.
PRG
4
The control unit goes back to the ESA menu. To exit programming, press the [PGM] and [
] buttons at the same time or, alternatively,
remove the power supply or wait 60 seconds.
PGM+
Note :The ESA function does not work when the charger is in charging mode. The ESA function must be disabled when there is the need of keeping the accessories output always
activated ,for example when a 24Vdc keypad or any other device that needs constant power supply is linked to the control panel.
Resetting the control unit (Res)
This function annuls all settings made, taking the control unit back to the initial conditions. It also deletes the settings of the autostart procedure.
NOTE: Any remote controls memorised in the radio receiver are not deleted.
1
Press the [PGM] button to access programming or if the control unit is already in the programming menu, press [
] until the Res func-
tion is displayed.
PMOT
RES
2
Press and hold [PGM], the RES message starts to flash quickly.
3
Release the [PGM] button when the PRG message is displayed.
The control unit is now taken to factory values.
PRG
4
The control unit goes back to the RES menu. To exit programming, press the [PGM] and [
] buttons at the same time or, alternatively,
remove the power supply or wait 60 seconds.
PGM+