A flow switch can be added to the unit, for units that were produced in 2020 or later.
On the circuit board with the display, there is the connection "FS" at the bottom left. These
are connected to the two contacts of the flow switch. If no flow is detected, neither acid nor
chlorine pump will run, and an alarm is generated.
Connecting a level switch
Two level switches can be added to the unit, for units produced in 2020 or later. For salt
electrolysis, only the "level switch "acid" is used.
On the circuit board with the display, there is a connection "WLH" and "WLL" in the middle
and right bottom. These are connected to the two contacts of the level switch. Connect
connection WLH to the level switch in the vessel with acid.
Upon low level detection, the respective pump will stop pumping and generate an alarm.
The Chlorinator
The Salt Chlorinator uses the most advanced microcomputer technology. It is both
multifunctional and easy to operate.
Never put the unit in the outlet of a frequency controller