ZPTX0010-P = unit 10gr/h , Pool for swimming pool 30 m3
ZPTX0018-P = unit 18gr/h , Pool for swimming pool 50 m3
ZPTX0030-P = appliance 30gr/h , Pool for swimming pool 90 m3
If you see that the redox is regularly far above the setpoint, you should reduce the intensity.
11.6) Flow switch; no , yes
Here you can enter whether the installation is equipped with a flow switch.
If you enter YES the device assumes that a flow switch is active. When there is a water flow,
a contact will close. When the contact is closed, the dosing pumps Ph and the salt
electrolysis can function. When there is no flow, the contact is open and so the dosing pump
and salt electrolysis will not work or will stop at a flow stop.
See below for connecting a flow switch to your unit.
11.7) Safety alarm: on or off or info
The alarm function is required to ensure safe operation of this unit and pool.
Alarm on:
The alarm screen comes on when:
- pH too high ( pH>8.5 or pH too low (pH < 5.5)
- Redox too high (>xx)
- pH or Redox measurement =0
- continuous dosing for 240 min
The alarm message disappears after the middle menu button is pressed. From
then on you can manually or automatically bring the values up to their level
by adding the right products and manner.
After the set time of the alarm has elapsed and the values are still not ok, the
alarm will be reactivated.