Specifications
Electrolysis Unit
ZLAX0016 ZLAX0020
50 m3 75m3
Chlorine control
EC 16 - 16g/h EC 20
20g/h
Pool connection
50mm to stick
Flow switch
Flow control on EC unit
Power supply
230V ~, 50 Hz
Installation
Attention!
○ The electrical installation should be done in such a way that:
- The electrolysis and acid pump cannot operate if the filter pump is not working.This can be
done by adding a flow switch/flow controller ZWMX3552-P to the installation or by using the
same power line as the filter pump.
○ Addition of pool chemicals should be done downstream of pool accessories such as heater, UV
lamp, filter etc.
○ It is recommended that the installation of the water treatment unit be in bypass confi
guration.
○ Install the water treatment unit on a solid base or against the wall (always vertical)
○ The product must be installed inside. If you want to do this outside, please contact your supplier.
○ The electronics (dosing devices) of the unit
must be installed inside. Make sure that - in case of
leakage - the water cannot run over the installation.
○ The electronics or the device itself must NEVER be connected to an output of a frequency
converter or frequency inverter.
○ The dosing device must
not be on the same power circuit as that of the frequency converter or
frequency inverter being used and it must be at least 3 m away from the dosing unit.