Error codes and corresponding solutions chlorinator

 

 
 

 
 
 
 
 
 
 
 
 
 
 

 

Error code  Reason for 

failure 

Remark 

Solution 

E1 

Cooling fin 
temperature is too 
high 

The temperature of the 
cooling fin is too high 

First check if error code E6 is present , if present 
, check if the temperature sensor is connected,if 
connected replace the sensor; 
If error code E6 is not present, check the 
installation. 

E2 

Water 
temperature is 
below the normal 

The error must be 
corrected manually 

First check if the error code E7 is present, if it is, 
check if the temperature sensor is attached. if it 
is, replace the sensor; 
If the E7 error code is not present. check 
whether the water is within the operating 
temperature range 

E3 

No water 

The normal 
temperature range is 
between 10-45 degrees 
Celsius. 

First check that the water level detector is 
attached. Check if water is leaking or if air is 
present. If water is present, wash the water 
level detector 

E4 

Salt concentration 
is too high 

Normal operation 
requires sufficient water 
in the chlorine supply  

First, use the salt meter to check the salt 
concentration in the pool. If the salt 
concentration level in the pool exceeds 3500 
ppm, drain a portion of the pool and replace it 
with fresh water. When the salt level of the 
pool reaches the normal salt level, the error 
code should disappear. And the unit should 
work again. 

E5 

Salt concentration 
is too low 

Normal salt 
concentration is 3500 
ppm 

First, use the salt meter to check the salt 
concentration in the pool. If the salt 
concentration level in the pool exceeds 3500 
ppm, drain part of the pool and add salt to the 
fresh water. When the salt level of the pool 
reaches the salt level of normal operation, the 
error code should disappear and the machine 
should function again. 

Summary of Contents for ZALX0030

Page 1: ...ZLAX0016 ZLAX0020 en ZALX0030 EC8 12 16 20 and 30...

Page 2: ...HS Salt electrolysis 1 Table of content 2 Specifications 4 Salt electrolysis installation 5 Structure diagram 7 Using the chlorinator 8 Warnings 14...

Page 3: ...eatures Durable the materials used are chlorine acid sulfuric acid salt and alkali resistant They can withstand long term exposure to pool water even with salt for salt electrolysis Simple operation t...

Page 4: ...ssories such as heater UV lamp filter etc It is recommended that the installation of the water treatment unit be in bypass configuration Install the water treatment unit on a solid base or against the...

Page 5: ...line suitable for PVC bonding The chlorinator should be installed in a well ventilated area to allow it to cool properly Do not install in an area where the electronic components of the chlorinator m...

Page 6: ...uch as automatic reset self cleaning lime removal and malfunction alarm Product Distinctive Facts Design for easy access to the titanium polar plate during installation and maintenance Users can choos...

Page 7: ...Structure diagram Model Chlorine productio n Ideal business location EC8 8g h unit suitable for swimming pools 40 m EC12 12g h unit suitable for swimming pools 60 m EC16 16g h unit suitable for swimmi...

Page 8: ...roduced 5 Parameter check press the acceleration key several times while the chlorinator is off to look up various parameters below Internal temperature chlorinator Water temperature Input voltage Ver...

Page 9: ...ror code if a problem occurs 2 Level indicator light 1 light stands for level 1 2 light stands for level 2 5 lights stand for 5 levels 3 Button for level control of chlorine production 4 boost indicat...

Page 10: ...k that the water level detector is attached Check if water is leaking or if air is present If water is present wash the water level detector E4 Salt concentration is too high Normal operation requires...

Page 11: ...e fault must be resolved manually change the power supply E9 Electrode does not work properly The fault must be remedied manually contact supplier for repair EA Electrode defective The fault will have...

Page 12: ...salt with approval number as a precursor of biocides of the country in which the unit is used The sodium chloride NaCl in the salt must be at least 99 6 1 3 Adding the right amount of salt Most swimmi...

Page 13: ...nly way to lower the salt concentration is to drain some of the pool water and replace it with fresh water 1 6 To reduce the loss of chlorine due to UV radiation on the water of the outdoor pool you s...

Page 14: ...safety glasses when working on the installation Disconnect power when working on the installation NEVER make any adjustments inside the dispensing equipment If you are not familiar with the pool filt...