Introduction
This manual contains all the necessary information for installation, troubleshooting and
maintenance. Read the manual thoroughly before opening or using the unit. The manufacturer
of this product will not be held responsible for any injury to and/or damage of the product
resulting from improper installation or unnecessary/incorrect maintenance. It is essential that
the instructions in this manual be followed at all times. Installation by qualified personnel is
required.
○ Only a qualified installer, cente
r, individual or an authorized dealer can repair this product.
○ Maintenance and operation should be performed according to the recommended time and
frequency, as stated in the manual.
○ Use only original standard parts. Failure to do so will void your w
arranty.
Features
○ Durable: the materials used are chlorine, acid (sulfuric acid), salt and alkali resistant. They can
withstand long-term exposure to pool water (even with salt for salt electrolysis).
○ Simple operation: the unit is very convenient to operate.
○ Low co
st: the operating cost is very low because when used correctly, the pool water never
turns green.
○ The pH and Redox probes need to be calibrated regularly, and the correct operation verified
by a proper color measurement method (e.g. Poollab ZWMX1060
Key elements :
○ Incomplete grounding of the pool pipes can have negative effects on the measurement results
and thus lead to abnormal pH and chlorine values in the pool.
○ Proper grounding is made as follows :
- The pool line after the filter pump is grounded through an in-line grounding to an
independent grounding post
- The pool line near the measuring probes is grounded through an in-line grounding to a
second independent grounding post
- Use only city water, not rainwater or well water