background image

 

 

 
 
 
 
 
 
 
 
 
 
 
1.4  

The correct way to add salt: 

A) Turn on the pool circulation pump and allow the water circulation to begin.  
B) Turn off the chlorinator. 
C) Test the current salt level of the pool. 
D) Calculate the amount of salt needed to add to the pool. 
E) Add salt to the pool around the side of the pool, allowing the salt to dilute quickly and 
evenly in the water. Do not allow salt to accumulate at the bottom of the pool. If necessary, 
stir the water at the bottom of the pool to allow the salt to completely dissolve. 
F)Run the circulation pump for 24 hours to allow the salt to distribute evenly in the pool.  
G)24 hours later, test the salt concentration of the pool again to see if it has reached the 
optimum level.  
H)When the pool salt concentration has reached the desired level, turn on the salt 
chlorinator and other equipment. Once the chlorinator has started, set the desired level of 
chlorine production. 
 
 

1.5 

Reduce the salt concentration:

 

The only way to lower the salt concentration is to drain some of the pool water and replace 
it with fresh water. 
 

1.6 

To reduce the loss of chlorine due to UV radiation on the water of the outdoor 

pool, you should add Cyanuric acid of 20-70 mg / l as a chlorine stabilizer. 
 
2.

 

Maintenance of saltchlorinator  

2.1  

Maintenance of the electrolysis cell 

To ensure proper operation of the salt chlorination plant, the electrolysis cell should be 
checked every three months after cleaning the filter. Follow the steps below to complete 
the check: 
 

A) Before removing the electrolysis cell, close the inlet and outlet valves and turn off 

the salt chlorinator for 5-10 minutes.  
 

B) After removing the electrolysis cell, check if there are flaky sediments, debris, 

light-colored layers in the inner surface.  Clean carefully with clean water . 
 

C) If there is a white calcified substance on the titanium plate, immerse the titanium 

plate in 4: 1 water hydrochloric acid to remove the calcified substance. For your safety, wear 
rubber gloves and eye protection.  
 

D) If there is significant sediment that cannot be removed on its own, contact the 

seller for professional advice. 
 
 
 
 
 
 
 
 
 

Summary of Contents for ZALX0030

Page 1: ...ZLAX0016 ZLAX0020 en ZALX0030 EC8 12 16 20 and 30...

Page 2: ...HS Salt electrolysis 1 Table of content 2 Specifications 4 Salt electrolysis installation 5 Structure diagram 7 Using the chlorinator 8 Warnings 14...

Page 3: ...eatures Durable the materials used are chlorine acid sulfuric acid salt and alkali resistant They can withstand long term exposure to pool water even with salt for salt electrolysis Simple operation t...

Page 4: ...ssories such as heater UV lamp filter etc It is recommended that the installation of the water treatment unit be in bypass configuration Install the water treatment unit on a solid base or against the...

Page 5: ...line suitable for PVC bonding The chlorinator should be installed in a well ventilated area to allow it to cool properly Do not install in an area where the electronic components of the chlorinator m...

Page 6: ...uch as automatic reset self cleaning lime removal and malfunction alarm Product Distinctive Facts Design for easy access to the titanium polar plate during installation and maintenance Users can choos...

Page 7: ...Structure diagram Model Chlorine productio n Ideal business location EC8 8g h unit suitable for swimming pools 40 m EC12 12g h unit suitable for swimming pools 60 m EC16 16g h unit suitable for swimmi...

Page 8: ...roduced 5 Parameter check press the acceleration key several times while the chlorinator is off to look up various parameters below Internal temperature chlorinator Water temperature Input voltage Ver...

Page 9: ...ror code if a problem occurs 2 Level indicator light 1 light stands for level 1 2 light stands for level 2 5 lights stand for 5 levels 3 Button for level control of chlorine production 4 boost indicat...

Page 10: ...k that the water level detector is attached Check if water is leaking or if air is present If water is present wash the water level detector E4 Salt concentration is too high Normal operation requires...

Page 11: ...e fault must be resolved manually change the power supply E9 Electrode does not work properly The fault must be remedied manually contact supplier for repair EA Electrode defective The fault will have...

Page 12: ...salt with approval number as a precursor of biocides of the country in which the unit is used The sodium chloride NaCl in the salt must be at least 99 6 1 3 Adding the right amount of salt Most swimmi...

Page 13: ...nly way to lower the salt concentration is to drain some of the pool water and replace it with fresh water 1 6 To reduce the loss of chlorine due to UV radiation on the water of the outdoor pool you s...

Page 14: ...safety glasses when working on the installation Disconnect power when working on the installation NEVER make any adjustments inside the dispensing equipment If you are not familiar with the pool filt...

Reviews: