48
Bell
fi res
English
Instructions for use and installation instructions
Appliance with operation in the separate operating unit (built in or otherwise).
• Gas control block and piping supplied as an pre-assembly.
First detach the bracket with the gas control block from the appliance.
Fit the separate control unit max. 50 cm from the appliance.
Fit the receiver in the top of the control unit. Connect the piezo cable, the 8-terminal
cable and the two thermocouple cables to the receiver (see Chapter 6: Electrical
Diagram).
Carefully move the bracket with the gas regulating block and piping
towards the control unit. Fit the bracket to the bottom of the
control unit. Make sure that you do not damage any of the piping
or detach any compression couplings while doing this.
After you have done this, check the compression couplings for leaks.
General:
Route all piping and cables from the operating unit to the appliance through an easily
accessible hollow cavity or a heat-resistant pipe of minimum Ø50 mm.
During subsequent installation of the operating unit, protect the gas regulating block and
piping against encasement by cement etc.
Important:
Cement and chalk can damage
the piping and can,
in turn, lead to gas leaks.
3.5.2 Connecting the concentric fl ue
Assemble the concentric fl ue system according to one of the examples in section 3.4.1,
fi gure 9 to 18 inclusive.
Make sure that all connections are completely gas tight.
3.5.3 Building in the appliance
Remove the front of the casing, if applicable.
Decide on positions of the vents (grilles above and below the fi replace) and, if
applicable, the hot air grids of the convection package.
The brickwork must be built up around the hearth. In connection with the hearth
expanding during burning: there must be at least 3 mm clearance on either side of the
appliance. Do not build up the brickwork farther than the angle irons/brackets (keep in
mind the thickness of any plastering!).
Connect up the convection package, if applicable.