42
Bell
fi res
English
Instructions for use and installation instructions
Never place the appliance directly on the fl oor, but
always make sure that there is a clearence of at least
5 cm between the appliance and the fl oor.
Never use combustible materials during the installation.
Ventilate the fi replace, by allowing vents above and
below the fi replace.
During installation of the gas fi re, a clearance of 3 mm
should be maintained on all sides of the appliance to
allow for expansion of the appliance during operation.
Do not insulate the appliance! Only the top and sides
may be fi tted with a strip of white, loose insulation wool
(heat-resistant to 1000°C), width 15 cm max. to protect
the wall.
Do not use fi breglass or Rockwool, or any other sort of
insulating material. These emit a pungent odour.
This is considered extremely unpleasant. They may also
cause discolouring of the column.
Flammable materials, such as curtains, should not
be placed in the vicinity of the gas fi re.
Minimum safe distance: 100 cm.
View Bell Room Divider Large: If the appliance is hung, use
the proper connecting method,
suitable for the particular wall
or partition.
The appliance may only be
installed on a wall constructed
from non-fl ammable material.
If desired, fi t a convection package to the appliance.
(See chapter 3.1)