10
Easymix 150 OPERATORS MANUAL
Before starting any maintenance or repairs, switch off motor, and isolate from the main power supply.
On completion of maintenance, check that the mixer functions correctly and that all guards are correctly fitted.
ELECTRIC MIXER
All portable electric appliances are dangerous if abused. This machine will only operate on one voltage. Check the
power supply to ensure it corresponds to the voltage as indicated on the rating label.
Make sure that the motor is switched off before you plug it into the power supply.
230v
- Always use a Residual Current Device ("RCD"), (earth leakage trip), plugged directly into the 230v socket. If
using an extension cable, plug it directly into the RCD.
110v
- When using a portable transformer it must have a minimum output of 2.5kw and to continuous rated.
The symbols on the ON/OFF switch are 0 (Red)=OFF and I (Green)=ON in accordance with international standards.
DO NOT use an extension cable between the transformer and the power supply.
Always ensure that the cable between the 110v mixer and transformer is a minium length of 3 metres.
Ensure cable is fitted with cable clip to the mixer frame at all times.
EXTENSION CABLES
If you need to use an extension cable it must be no longer than 30 metres (100 feet) in length. The wire section must be
1.5mm
2
on 230v. Ensure that the extension cable is carefully laid out avoiding liquids, sharp edges and places where
vehicles might run over it. Avoid allowing the extension cable to be trapped underneath the mixer. Unroll it fully or it will
overheat and could catch fire. Make sure that any extension cable connections are dry and safe.
COMBUSTION ENGINES
Check oil regularly, level engine up when doing so. For Initial engine fill or top up use a suitable engine oil of a 10W/30
grade. In your own interests read the makers instruction leaflet issued with the machine before starting up.
CLEANING
Wipe off any external material.
DO NOT
use petrol, turpentine, lacquer or paint thinner, dry cleaning fluids or similar
products. Never let any liquids near the engine/motor. Use 1” gravel and clean water to clean the inside of the drum.
DO NOT
use bricks etc. as this will damage the drum.
FRAME
The hole on the underside of the frame is to drain away any water.
BELT
All Belle mixers Electric/Petrol are fitted with a preset tensioned toothed belt. No adjustment is necessary.
DO NOT try to adjust with the motor running.
GEARBOX
The factory has preset the gearbox oil level.
Before inspecting the gearbox oil level, make sure the gearbox is cold before removing
the filler plug. Top up with EP90 or similar gear oil in the mix position to the level of
the filler plug.
Ensure the extension lead is always unplugged before
the motor cover is removed.
MAINTENANCE
GB
Oil Fill Plug
Mixing Position
Oil Filling Position