Specification for the C106 Controller
Lock
Output Voltage:
Same as Input Voltage
Load (maximum):
0.5A (load inductive or resistive)
Note : Inductive loads such as Maglocks must have suitable transient voltage
suppression fitted, e.g. a diode or MOV
Power (C + & H -)
Input Voltage:
12V to 14V
Current (maximum):
60mA
Dimensions
C106 Keypad:
90mm x 62mm x 33mm
Panel Cut-out:
87.75mm x 59.7mm
Panel Thickness
2mm or 3mm