CS106/BL106 Combined Door Entry and Coded Access
10
Cable Requirements
Cable Types
0.5mm:
Twisted pair, e.g. BT spec CW1308 or CAT5 UTP
1.0mm:
1.0mm
2
‘Twin mains flex’
Connections
No. of cores Cable length
Core diameter
Power supply
2
up to 15M
up to 50M
0.5mm
1.0mm
Lock release (up to
500mA)
2
up to 5M
up to 25M
0.5mm
1.0mm
Time Clock
4
100M max.
0.5mm
Exit button
2
100M max.
0.5mm
In most cases cable length restrictions should not present a problem, however
where longer lengths are required please refer to the manufacturer for advice.