CS106/BL106 Combined Door Entry and Coded Access
39
For optimum clarity of speech it is strongly recommended that this system is
installed using twisted-pair telephone cable (e.g. type CW1308). Use one of the
pairs for the R & O connection between the speech unit and the telephone.
Connections
No. of cores
Core
diameter
Cable
length
Phone
4 + 1 per phone
0.5mm
100M max.
Power Supply
2
0.5mm
1.0mm
up to 15M
up to 50M
Lock release (up to 500mA)
2
0.5mm
1.0mm
up to 5M
up to 25M
Time clock
4
0.5mm
100M max.
Exit
2
0.5mm
100M max.
Trades Button
2
0.5mm
100M max.
In most cases cable length restrictions should not present a problem, however
where longer lengths are required please refer to the manufacturer for advice.