Safety-Related Electrical, Physical, and Environmental Information
Physical specifications
Stinger® MS+ Getting Started Guide
C-3
EMI class
The Stinger product belongs to EMI class A.
Minimum ground wire size
The DSL lines connected to the Stinger FS and Stinger FS+ can be subject to lightning
surges. These surges must be discharged to ground through an adequate ground wire.
An adequate ground wire must present a resistance of approximately 0.02 ohms to a
surge of 500 amps. The wire gauges shown in Table C-3 are appropriate for the wire
lengths indicated.
Lucent Technologies does not recommend use of a ground wire longer than 100 feet
(30.48m).
Physical specifications
Table C-4 describes the Stinger MS+ physical specifications.
STGR-LIM-E1-24
04DU9-1KN
6.0N
RJ-48C
STGR-LIM-E1-24
04DU9-1SN
6.0N
RJ-48C
STGR-LIM-E1-24
04DU9-1ZN
6.0N
RJ-48C
Table C-2.
Stinger T1 module USOC jacks and codes (Continued)
Model name
Facility interface
code
Service order code
Jack type
Table C-3.
Stinger FS minimum ground wire sizes
Length
Wire gauge
0 to 10 feet (0m to 3.05m)
12 AWG (3.31mm²)
10 to 25 feet (3.05m to 7.62m)
9 AWG (6.63mm²)
25 to 50 feet (7.62m to
15.24m)
6 AWG (13.3mm²)
50 to 100 feet (15.24m to
30.48m)
3 AWG (26.7mm²)
Table C-4.
Stinger MS+ physical specifications
Specification
Description
ATM standards
ATM Forum UNI (Version 3.0 and Version 3.1), ATM
Forum Interim Interswitch Signaling Protocol (IISP)