background image

Installation RSR20/RSR30

Release 06 07/2021

3

Contents

Important information

5

Safety instructions

7

About this manual

16

Key

17

1

Description

18

1.1

General device description

18

1.2

Description of the device variants

19

1.2.1 Combination options RSR20/RSR30

19

1.2.2 Port number and media for RSR20-...

21

1.2.3 Port number and media for RSR30-...

25

1.3

Power supply

30

1.3.1 Supply voltage with characteristic value C

30

1.4

Ethernet ports

30

1.4.1 10/100/1000 Mbit/s twisted pair port

31

1.4.2 10/100 Mbit/s twisted pair port

31

1.4.3 100/1000 Mbit/s F/O port

31

1.4.4 1000 Mbit/s F/O port

31

1.4.5 100 Mbit/s F/O port

32

1.4.6 Gigabit combo port

32

1.4.7 Pin assignments

33

1.5

Display elements

34

1.5.1 Device state

34

1.5.2 Port status

36

1.6

Management interfaces

36

1.6.1 USB interface

36

1.6.2 V.24 interface (external management)

37

1.7

Signal contact

38

2

Installation

39

2.1

Checking the package contents

39

2.2

Installing and grounding the device

39

Summary of Contents for HIRSCHMANN RSR20 Series

Page 1: ...6 07 2021 Technical support https hirschmann support belden com User Manual Installation Industrial Ethernet Rail Switch Rugged RSR20 RSR30 Family 5 7 9 6 8 10 5 7 9 6 8 10 3 5 7 9 4 6 8 10 3 5 7 9 4...

Page 2: ...rformance features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the b...

Page 3: ...voltage with characteristic value C 30 1 4 Ethernet ports 30 1 4 1 10 100 1000 Mbit s twisted pair port 31 1 4 2 10 100 Mbit s twisted pair port 31 1 4 3 100 1000 Mbit s F O port 31 1 4 4 1000 Mbit s...

Page 4: ...2 4 2 Supply voltage with the characteristic value C 44 2 4 3 Signal contact 44 2 5 Mounting the terminal block 45 2 6 Operating the device 45 2 7 Connecting data cables 45 2 8 Filling out the inscrip...

Page 5: ...injury or death If this symbol is displayed in addition to a safety instruction of the type Danger or Warning it means that there is a danger of electric shock and failure to observe the instructions...

Page 6: ...6 Installation RSR20 RSR30 Release 06 07 2021 NOTICE NOTE provides information about procedures that do not involve the risk of injury...

Page 7: ...unctioning the device turn off the supply voltage and return the device to Hirschmann for inspection Intended usage Use the product only for the application cases described in the Hirschmann product i...

Page 8: ...casing Never insert pointed objects narrow screwdrivers wires etc into the device or into the connection terminals for electric conductors Do not touch the connection terminals Keep the ventilation sl...

Page 9: ...voltage Connect only safety extra low voltage circuits with voltage restrictions in line with IEC EN 60950 1 to the supply voltage connections and signal contacts Exclusively connect a supply voltage...

Page 10: ...e protective conductor before connecting the wires for the supply voltage If your device comprises a 2nd supply voltage connection of this type First connect the protective conductor before connecting...

Page 11: ...d brancher tant que le circuit est sous tension moins que l emplacement soit connu pour ne contenir aucune concentration de gaz inflammable Avertissement Risque d explosion La substitution de tout com...

Page 12: ...IP54 enclosure HAZARDOUS LOCATION Non Hazardous Location 1 RSRxx Non Hazardous Location Hazardous Location Power supply redundant Type C 24 48 V DC DXOW FRQWDFWV TXLSPHQW ZLWK QRQLQFHQGLYH HOG ZLULQJ...

Page 13: ...are met C a i C Cable L a i L Cable Nonincendive field wiring circuits must be wired in accordance with the National Electrical Code NEC NFPA 70 article 501 Nonincendive Field Wiring Parameters Entity...

Page 14: ...onformity declaration will be at the disposal of the relevant authorities at the following address Hirschmann Automation and Control GmbH Stuttgarter Str 45 51 72654 Neckartenzlingen You find the EU c...

Page 15: ...d 2 this device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A di...

Page 16: ...ription safety instructions a description of the display and the other information that you need to install the device Documentation mentioned in the User Manual Installation that is not supplied with...

Page 17: ...Installation RSR20 RSR30 Release 06 07 2021 17 Key The symbols used in this manual have the following meanings Listing Work step Subheading...

Page 18: ...set up switched industrial Ethernet networks that conform to the IEEE 802 3 standard The devices work without a fan The voltage supply can be redundant if required The following installation options a...

Page 19: ...ast Ethernet ports 10 100 Mbit s 1 2 1 Combination options RSR20 RSR30 The product designation of your device is made from combining the desired product characteristics in accordance with the followin...

Page 20: ...100 1000 Mbit s Ethernet O6 1 SFP slot 1000 Mbit s Ethernet T1 1 Twisted Pair TX RJ45 socket M2 1 Multimode FX DSC M3 1 Multimode FX MTRJ M4 1 Multimode FX DST S2 1 Singlemode FX DSC S4 1 Signlemode...

Page 21: ...n Position 1 to 10 Position 11 to 12 Position 13 to 14 Position 15 to 16 Position 17 Position 18 to 19 Position 20 to 21 RSR20 0900 JJ M3 T1 CC P MM M2 M4 S2 S4 L2 G2 NN VV UU LL GG Table 2 Combinatio...

Page 22: ...Position 19 C 2 pin terminal block Voltage range See General technical data on page 53 7 Connection for signal contact 2 8 Grounding screw 9 LED display elements for port status 10 port 4 to 9 LAN on...

Page 23: ...IEEE 802 3 10BASE T 100BASE TX Connection type RJ45 socket 11 port 1 to 2 LAN port for Fiber optic cable Standard IEEE 802 3 100BASE FX Connection type depending on device variant DSC DST Table 5 RSR2...

Page 24: ...EE 802 3 10BASE T 100BASE TX Connection type RJ45 socket Table 6 RSR20 device variants with 8 twisted pair ports RJ45 1 to 9 See table 4 on page 22 Table 7 RSR20 device variants with 3 fiber optic por...

Page 25: ...T 100BASE TX Connection type RJ45 socket 11 Ports 1 to 3 LAN port for Fiber optic cable Type of fiber Multimode Standard IEEE 802 3 100BASE FX Connection type MTRJ Position 1 to 10 Position 11 to 12 P...

Page 26: ...t 11 Ports 1 to 3 combo ports LAN port for Fiber optic cable Standard IEEE 802 3 100BASE FX ISO IEC 8802 03 1000BASE SX LX Connection type SFP slot LAN port for Twisted pair Standard ISO IEC 8802 03 1...

Page 27: ...EEE 802 3 100BASE FX Connection type SFP slot 12 port 1 to 2 combo ports LAN port for Fiber optic cable Standard IEEE 802 3 100BASE FX ISO IEC 8802 03 1000BASE SX LX Connection type SFP slot LAN port...

Page 28: ...pe RJ45 socket 11 port 3 to 4 LAN port for Fiber optic cable Standard IEEE 802 3 100BASE FX Connection type SFP slot 12 port 1 to 2 LAN port for Fiber optic cable Standard ISO IEC 8802 03 1000BASE SX...

Page 29: ...11 port 1 to 2 combo ports LAN port for Fiber optic cable Standard IEEE 802 3 100BASE FX ISO IEC 8802 03 1000BASE SX LX Connection type SFP slot LAN port for Twisted pair Standard ISO IEC 8802 03 10B...

Page 30: ...ristic value C on page 30 1 4 Ethernet ports You can connect end devices and other segments to the device ports using twisted pair cables or optical fibers F O 1 to 9 See table 4 on page 22 10 port 3...

Page 31: ...to connect network components according to the IEEE 802 3 10BASE T 100BASE TX standard This port supports Autonegotiation Autopolarity Autocrossing if autonegotiation is activated 100 Mbit s half dup...

Page 32: ...EE 802 3 100BASE FX standard This port supports Full or half duplex mode Default setting Full duplex Note Verify that the LH ports are connected only with LH ports SM ports only with SM ports and MM p...

Page 33: ...ver or Technical standard IEEE 802 3 1000BASE SX LX Connection type 1 Gigabit Ethernet SFP transceiver Table 16 Combo ports Connection options RJ45 Pin 10 100 Mbit s 1000 Mbit s PoE MDI mode 1 TX BI_D...

Page 34: ...ion of the whole device Figure 2 Device status LEDs P Power green yellow LED Meaning Glowing green Device variants with 1 power supply unit Supply voltage is on Glowing yellow Device variants with 2 p...

Page 35: ...act 1 red lights up The signal contact is open it is reporting a detected error none The signal contact is closed it is not reporting any detected errors R1 Signal contact 1 yellow lights up The signa...

Page 36: ...interface for the local connection of an AutoConfiguration Adapter ACA22 USB It is used for saving loading the configuration data and diagnostic information and for loading the software The USB inter...

Page 37: ...and Line Interface CLI and to the system monitor The socket housing is electrically connected to the front panel of the device The V 24 interface is electrically insulated from the supply voltage Figu...

Page 38: ...connected to a power supply The signal contact allows you to control external devices or monitor device functions In the configuration you specify how the device uses the signal contact You will find...

Page 39: ...illing out the inscription label 2 1 Checking the package contents Proceed as follows Check whether the package includes all items named in the section Scope of delivery on page 61 Check the individua...

Page 40: ...ground of the industrial connectable twisted pair lines is connected to the lower panel as a conductor 2 2 2 Mounting on a vertical flat surface You have the option of attaching the device to a verti...

Page 41: ...e into the rail and press it down against the rail until it snaps into place Fasten the wall plate see on page 61 Accessories on a level wall surface using four screws 2 2 3 Grounding the device Use a...

Page 42: ...from the SFP transceiver 2 Push the SFP transceiver with the lock closed into the slot until it latches in 3 2 4 Connecting the terminal block The supply voltage and the signal contacts are connected...

Page 43: ...Note With non redundant supply of the mains voltage the device reports a power failure You can avoid this message by changing the configuration in the management or with power supply units of the same...

Page 44: ...htening the terminal screws With a non redundant supply of the supply voltage the device reports the loss of a supply voltage You can prevent this message by changing the configuration in the Manageme...

Page 45: ...ission between the buildings When using copper cables provide a sufficient separation between the power supply cables and the data cables Ideally install the cables in separate cable channels Verify t...

Page 46: ...1 2 8 Filling out the inscription label The information field for the IP address helps you identify your device Figure 9 Label area for IP address of device 1 IP address of device label area 2 MAC add...

Page 47: ...n via BOOTP Configuration via DHCP Configuration via DHCP Option 82 Configuration using AutoConfiguration Adapter Default settings IP address The device looks for the IP address using DHCP Management...

Page 48: ...private The device prompts you to type in a new password Type in your new password To help increase security choose a password that contains at least 8 characters which includes upper case characters...

Page 49: ...pends on the installation conditions of the device for example the distance from other devices or other objects and the output of neighboring devices The temperature displayed in the CLI Command Line...

Page 50: ...acts and the switching function depending on the frequency of the switching operations Hirschmann is continually working on improving and developing their software Check regularly whether there is an...

Page 51: ...oceed as follows Disconnect the data cables Disable the supply voltage Disconnect the terminal blocks Disconnect the grounding Insert a screwdriver horizontally below the casing into the locking gate...

Page 52: ...ional Figure 10 De installing SFP transceivers De installation sequence Perform the following work steps Open the locking mechanism of the SFP transceiver 1 Pull the SFP transceiver out of the slot vi...

Page 53: ...t and right device side 0 79 in 2 cm Ambient air temperaturea a Temperature of the ambient air at a distance of 2 in 5 cm from the device Devices with operating temperature characteristic value S Stan...

Page 54: ...30 Release 06 07 2021 Dimension drawings Drill holes drawing for wall mounting plate mm inch 120 4 72 6 99 0 28 120 83 4 76 145 3 5 72 136 44 5 37 120 4 72 147 6 5 82 mm inch 100 3 94 157 6 19 5 4 0 2...

Page 55: ...4 6 Conducted interference voltage 50kHz 80MHz 10 V 10 V IEC EN 61000 4 12 Damped oscillation DC Power line AC Power line Data line 2 5kV line ground 1kV line line 2 5kV line ground 1kV line line 2 5...

Page 56: ...2 1 Cold 40 C 16 hours 40 C 16 hours IEC 60068 2 2 Dry heat 85 C 16 hours 85 C 16 hours IEC 60068 2 30 Relative humidity 95 non condensed 55 C 4 cycles 95 non condensed 55 C 4 cycles IEC 60068 2 6 Vi...

Page 57: ...00 MHz km MX LC EEC MM 1310 nm 50 125 m 0 dB 12 dB 0 mi 0 93 mi 0 km 1 5 km 1 0 dB km 800 MHz km MX LC EEC MM 1310 nm 62 5 125 m 0 dB 12 dB 0 mi 0 31 mi 0 km 0 5 km 1 0 dB km 500 MHz km LX LC MM 1310...

Page 58: ...ed Product code M SFP BIDI Mo dea a MM Multimode SM Singlemode LH Singlemode Longhaul Wave length TX Wave length RX Fiber System attenuat ion Example for F O cable lengthb b Including 3 dB system rese...

Page 59: ...104 km 0 25 dB km 19 ps nm km LH LC SM 1550 nm 9 125 m 10 dB 29 dB 14 29 mi 86 99 mi 55 km 140 km 0 18 dB kmc c With ultra low loss optical fiber 18 ps nm km Table 22 Fiber port 100BASE FX SFP fiber o...

Page 60: ...stallation RSR20 RSR30 Release 06 07 2021 10 100 1000 Mbit s twisted pair port Length of a twisted pair segment max 328 ft 100 m for Cat5e cable Table 24 Network range 10 100 1000 Mbit s twisted pair...

Page 61: ...Mbit s 14 W 48 Btu IT h 2 SFP slot 1000 Mbit s and 8 TX port 100 Mbit s 12 W 41 Btu IT h 3 FX port 100 Mbit s and 6 TX port 100 Mbit s 14 W 48 Btu IT h 2 FX port 100 Mbit s and 6 TX port 100 Mbit s 12...

Page 62: ...Fast Ethernet SFP transceiver Order number M FAST SFP TX RJ45 942 098 001 M FAST SFP TX RJ45 EEC 942 098 002 The following operating conditions apply to twisted pair transceivers Usable with HiOS as o...

Page 63: ...el Ships BV CSA C22 2 No 213 Canadian National Standard s for Nonincendive Electrical Equipment for Use in Class I Division 2 Hazardous Locations EN 50121 4 Railway applications EMC emitted interferen...

Page 64: ...n the Hirschmann website at www hirschmann com in the product information The device generally fulfills the technical standards named in their current versions IEEE 802 1Q Virtual LANs VLANs MRP Spann...

Page 65: ...etitors on three counts with its complete range of innovative services Consulting incorporates comprehensive technical advice from system evaluation through network planning to project planning Traini...

Page 66: ......

Reviews: