42
Installation RSR20/RSR30
Release 06 07/2021
2.3
Installing an SFP transceiver (optional)
Prerequisites:
Exclusively use Hirschmann SFP transceivers.
Figure 7: Installing SFP transceivers: Installation sequence
Perform the following work steps:
Take the SFP transceiver out of the transport packaging (1).
Remove the protection cap from the SFP transceiver (2).
Push the SFP transceiver with the lock closed into the slot until it latches
in (3).
2.4
Connecting the terminal block
The supply voltage and the signal contacts are connected via a 2-pin terminal
block with screw lock.
Note:
The torque for tightening the terminal block for the signal contact on
the device is 3 lb-in (0.34 Nm).
WARNING
ELECTRIC SHOCK
Exclusively connect a supply voltage that corresponds to the type plate of
your device.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.
3