Installation OCTOPUS OS3
Release 03 08/2020
25
1.5
Ethernet ports
You have the option to connect end devices or other segments to the ports
of the device via twisted pair cables.
You find information on pin assignments for making patch cables here:
10/100 Mbit/s twisted pair port
This port is a 4-pin, “D”-coded M12 socket.
The 10/100 Mbit/s twisted pair port allows you to connect network
components according to the IEEE 802.3 10BASE-T/100BASE-TX
standard.
This port supports:
10 Mbit/s half-duplex mode, 10 Mbit/s full duplex mode
100 Mbit/s half-duplex mode, 100 Mbit/s full duplex mode
Autocrossing (if autonegotiation is activated)
Autonegotiation
Autopolarity
The PoE power is supplied via the wire pairs transmitting the signal
(phantom voltage).
Delivery state: Autonegotiation activated
The pin assignment corresponds to MDI-X.
10/100/1000 Mbit/s twisted pair port
This port is an 8-pin, “X”-coded M12 socket.
The 10/100/1000 Mbit/s twisted pair port allows you to connect network
components according to the IEEE 802.3 10BASE-T/100BASE-TX/
1000BASE-T standard.
This port supports:
10 Mbit/s half-duplex mode, 10 Mbit/s full duplex mode
100 Mbit/s half-duplex mode, 100 Mbit/s full duplex mode
1000 Mbit/s full duplex
Autocrossing (if autonegotiation is activated)
Autonegotiation
Autopolarity
The pin assignment corresponds to MDI-X.