26
Installation OCTOPUS OS3
Release 03 08/2020
1.6
Pin assignments
Note:
If you operate a GE port with Fast Ethernet, only the pins 1 to 4 are
active.
Supply voltage characteristic
value BB, HH, PP, QQ
Pin Function
Type
1
P1+ Plus terminal of supply voltage 1
5-pin M12
connector,
“L”-coded
2
P2-
Minus terminal of supply voltage 2
3
P1-
Minus terminal of supply voltage 1
4
P2+ Plus terminal of supply voltage 2
5
FE
Functional earth connection
Table 6:
Pin assignments: Supply voltage characteristic value BB, HH, PP, QQ
Supply voltage
characteristic value M9,N9
Pin Function
characteristic
value M9
Function
characteristic
value N9
Type
1
L
Conductor
+
Plus terminal of
supply voltage
5-pin M12
connector,
“K”-coded
2
Do not use
Do not use
3
N
Neutral
conductor
-
Minus terminal of
supply voltage
4
Do not use
Do not use
5
PE Protective earth
connection
PE Protective earth
connection
Table 7:
Pin assignments: Supply voltage characteristic value M9, N9
GE port
Pin Function
PoE/PoE+
Type
1
BI_DB+
Negative V
PSE
8-pin M12
socket, “X”-
coded
2
BI_DB-
Negative V
PSE
3
BI_DA+
Positive V
PSE
4
BI_DA-
Positive V
PSE
5
BI_DC+
-
6
BI_DC-
-
7
BI_DD-
-
8
BI_DD+
-
Table 8:
Pin assignments: GE port
1
2
3
4
5
1
2
3
4
5
1
2
7
4
3
5
6
8
Summary of Contents for HIRSCHMANN OCTOPUS OS3