Installation OCTOPUS OS3
Release 03 08/2020
47
Back-up fuse for each voltage input
Nominal rating:
max. 20 A
Characteristic:
slow blow
Peak inrush current
8 A
Connection for functional ground
See “Grounding the device” on page 36.
Current integral I²t
<1.5 A²s
Max. PoE power
Nominally
60 W
a. When using the supplied plug.
Supply voltage with the characteristic value M9
Rated voltage range
110 V AC ... 230 V AC, 50 Hz ... 60 Hz
Voltage range including maximum
tolerances
88 V AC ... 265 V AC, 47 Hz ... 63 Hz
Connection type
5-pin, “K”-coded M12 plug
Tightening torque
5.3 lb-in (0.6 Nm)
Wire diameter
AWG16 (1.5 mm²)
a
a. When using the supplied plug.
Power loss buffer
PoE:
110 V non-PoE:
230 V non-PoE:
>13 ms
>50 ms
>110 ms
Overload current protection on the device Non-replaceable fuse
Back-up fuse for each voltage input
Nominal rating:
max. 20 A
Characteristic:
slow blow
Peak inrush current
3.5 A
Connection for protective grounding
See “Grounding the device” on page 36.
Current integral I²t
non-PoE
<1.5 A²s
PoE
<1 A²s
Max. PoE power
Nominally
60 W
Table 21: Supply voltage with characteristic value M9
Supply voltage with the characteristic value N9
Rated voltage
72 V DC ... 110 V DC
Voltage range including maximum
tolerances
50.4 V DC ... 138 V DC
Connection type
5-pin, “K”-coded M12 plug
Tightening torque
5.3 lb-in (0.6 Nm)
Wire diameter
AWG16 (1.5 mm²)
a
Power loss buffer
PoE:
72 V non-PoE:
110 V non-PoE:
>11 ms
>16 ms
>40 ms
Overload current protection on the device Non-replaceable fuse
Back-up fuse for each voltage input
Nominal rating:
max. 20 A
Characteristic:
slow blow
Peak inrush current
3.5 A
Connection for protective grounding
See “Grounding the device” on page 36.
Table 22: Supply voltage with characteristic value N9
Supply voltage with characteristic value QQ
Table 20: Supply voltage with characteristic value QQ
Summary of Contents for HIRSCHMANN OCTOPUS OS3
Page 60: ......