background image

38

Installation OCTOPUS OS3

Release 03 08/2020

2.4

Connecting the supply voltage

Mount the power supply cable to the power supply connector of the 
device.
You find the prescribed tightening torque in chapter:

“General data” on page 45

Enable the supply voltage.

Note: 

Applies to device variants featuring supply voltage with characteristic 

value PP: 
Exclusively use a PoE power supply unit with galvanic isolation.
Hirschmann has tested the power supply unit PC150/110V/54V and 
recommends its use. You find the order number for the power supply unit, 
which is available as accessory, under:

“Accessories” on page 57

Note: 

For use cases according to EN 50155, exclusively use external front 

end power supply units of type PC150/110V/54V, or else the suitability of the 
device for this use case is void.

 WARNING

ELECTRIC SHOCK

 
Connect only a supply voltage that corresponds to the type plate of your 
device.
 

Failure to follow these instructions can result in death, serious injury, 
or equipment damage.

Summary of Contents for HIRSCHMANN OCTOPUS OS3

Page 1: ...Installation OCTOPUS OS3 Release 03 08 2020 Technical support https hirschmann support belden com User Manual Installation Managed Ethernet Switch OCTOPUS OS3 ...

Page 2: ...he performance features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirschmann reserves the right to change the contents of this document without prior notice Hirschmann can give no guarantee in respect of the correctness or accurac...

Page 3: ...assignment 22 1 4 Power supply 23 1 4 1 Supply voltage with the characteristic value BB 23 1 4 2 Supply voltage with characteristic value HH 23 1 4 3 Supply voltage with characteristic value PP 23 1 4 4 Supply voltage with the characteristic value QQ 24 1 4 5 Supply voltage with the characteristic value N9 24 1 4 6 Supply voltage with the characteristic value M9 24 1 5 Ethernet ports 25 1 6 Pin as...

Page 4: ...Settings 40 3 1 Default settings 40 3 2 First login Password change 41 4 Monitoring the ambient air temperature 42 5 Maintenance and service 43 6 Disassembly 44 6 1 Removing the device 44 7 Technical data 45 7 1 General data 45 7 2 Supply voltage 45 7 3 Power consumption power output 48 7 4 Signal contact 49 7 5 Climatic conditions during operation 49 7 6 Climatic conditions during storage 49 7 7 ...

Page 5: ...Installation OCTOPUS OS3 Release 03 08 2020 5 12 Accessories 57 13 Underlying technical standards 58 A Further support 59 ...

Page 6: ...ds Obey all safety messages that follow this symbol to avoid possible injury or death The additional of this symbol to a Danger or Warning safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed This symbol points out the dangers posed by hot device surfaces In connection with safety notes the disregard of these instructions...

Page 7: ...ce to Hirschmann for inspection National and international safety regulations Verify that the electrical installation meets local or nationally applicable safety regulations Certified usage Use the product only for the application cases described in the Hirschmann product information including this manual Operate the product only according to the technical specifications See Technical data on page...

Page 8: ...tall the device indoors Exclusively mount the device on a suitable flat metal surface to ensure adequate cooling of the device Device casing Only technicians authorized by the manufacturer are permitted to open the casing Never insert pointed objects narrow screwdrivers wires etc into the device or into the connection terminals for electric conductors Do not touch the connection terminals Keep the...

Page 9: ...re connecting the electrical wires always verify that the requirements listed are complied with General requirements for connecting electrical wires The following requirements apply without restrictions The electrical wires are voltage free The cables used are permitted for the temperature range of the application case Relevant for North America Exclusively use 60 75 C 140 167 F or 75 C 167 F copp...

Page 10: ... V DC The power supply is potential free For power supply modules capable of PoE exclusively use a potential free SELV power supply The following requirements apply alternatively Relevant when the device is supplied via 1 voltage input Relevant for North America The power supply complies with the requirements according to NEC Class 2 Relevant when the device is supplied via 2 voltage inputs Releva...

Page 11: ...med EU directive s the EU conformity declaration will be at the disposal of the relevant authorities at the following address Hirschmann Automation and Control GmbH Stuttgarter Str 45 51 72654 Neckartenzlingen Germany www hirschmann com The device can be used in the industrial sector Interference immunity EN 61000 6 2 Emitted interference EN 55032 Safety EN 62368 1 You find more information on tec...

Page 12: ...to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful in...

Page 13: ...cription safety instructions a description of the display and the other information that you need to install the device Documentation mentioned in the User Manual Installation that is not supplied with your device as a printout can be found as PDF files for downloading on the Internet at https www doc hirschmann com ...

Page 14: ...14 Installation OCTOPUS OS3 Release 03 08 2020 Key The symbols used in this manual have the following meanings Listing Work step Subheading ...

Page 15: ...e of functions which the manuals for the operating software inform you about You find these manuals as PDF files on the Internet at http www doc hirschmann com The Hirschmann network components help you ensure continuous communication across all levels of the company The Network Management Software Industrial HiVision provides you with options for smooth configuration and monitoring You find furth...

Page 16: ...10 100 Mbit s PoE PoE ports 12 13 Number 10a 100 1000 Mbit s PoE PoE ports 00 0 10 100 1000 Mbit s PoE PoE ports 08 8 10 100 1000 Mbit s PoE PoE ports 16 16 10 100 1000 Mbit s PoE PoE ports 24 24 10 100 1000 Mbit s PoE PoE ports 14 15 Number 10a 100 Mbit s ports 00 0 10 100 Mbit s ports 08 8 10 100 Mbit s ports 16 16 10 100 Mbit s ports 16 17 Number 10a 100 1000 Mbit s ports 08 8 10 100 1000 Mbit ...

Page 17: ...voltage range 88 V AC 265 V AC 47 Hz 63 Hz Connection type 5 pin M12 connector N9 Rated voltage 72 V DC 110 V DC Rated voltage range 50 4 V DC 138 V DC Connection type 5 pin M12 connector 28 29 Certificates and declarations Z9 CE FCC EN 61131 EN 62368 1 Y9 Z9 cUL 61010 S9 Z9 EN 50121 4 EN 50155 30 31 Software packages 99 Reserved UR Unicast Routing MR Unicast Multicast Routing 32 33 Customer speci...

Page 18: ... or L coded M12 plug 5 LED display elements for port status 6 24 10 100 1000 Mbit s twisted pair port or 10 100 Mbit s twisted pair port Device variants OS3 3x 8 pin X coded M12 socket or 4 pin D coded M12 socket Device variants OS3 4x 8 pin X coded M12 socket 7 Slot hole for mounting on a flat surface 8 LED display elements for device status 9 Ground connection 10 Ground connection alternatively ...

Page 19: ...ed M12 plug 5 LED display elements for port status 6 16 10 100 1000 Mbit s twisted pair port or 10 100 Mbit s twisted pair port Device variants OS3 3x 8 pin X coded M12 socket or 4 pin D coded M12 socket Device variants OS3 4x 8 pin X coded M12 socket 7 Slot hole for mounting on a flat surface 8 LED display elements for device status 9 Ground connection 10 Ground connection alternatively Table 3 F...

Page 20: ...ed M12 plug 5 LED display elements for port status 6 8 10 100 1000 Mbit s twisted pair port or 10 100 Mbit s twisted pair port Device variants OS3 3x 8 pin X coded M12 socket or 4 pin D coded M12 socket Device variants OS3 4x 8 pin X coded M12 socket 7 Slot hole for mounting on a flat surface 8 LED display elements for device status 9 Ground connection 10 Ground connection alternatively Table 4 Fr...

Page 21: ... ports are connected with each other Thus signals can also be transmitted in a voltage free state via Uplink port pairs 1 First uplink port pair Port 5 and 6 Bypass functionality for device variants OS3 R6R6 2 Second uplink port pair Port 7 and 8 Bypass functionality for device variants OS3 R6R6 Table 5 Front view using the example OCTOPUS3 40 1 2 ...

Page 22: ...nstallation OCTOPUS OS3 Release 03 08 2020 1 3 5 Port assignment Figure 1 Port assignment Port assignment OCTOPUS OS3 Note The numerical sequence of the port assignment is identical for every device variant ...

Page 23: ... the device reports the loss of a supply voltage You can prevent this message by applying the supply voltage via both inputs or by changing the configuration in the Management A 5 pin L coded M12 plug is available for the redundant supply of the device See Device name and product code on page 16 1 4 3 Supply voltage with characteristic value PP The supply voltage can be connected redundantly Both ...

Page 24: ...ed M12 plug is available for the redundant supply of the device See Device name and product code on page 16 1 4 5 Supply voltage with the characteristic value N9 The power is supplied via a 5 pin K coded M12 plug For information about the position on the device see chapter Device views on page 18 Further information See Device name and product code on page 16 1 4 6 Supply voltage with the characte...

Page 25: ...plex mode 100 Mbit s full duplex mode Autocrossing if autonegotiation is activated Autonegotiation Autopolarity The PoE power is supplied via the wire pairs transmitting the signal phantom voltage Delivery state Autonegotiation activated The pin assignment corresponds to MDI X 10 100 1000 Mbit s twisted pair port This port is an 8 pin X coded M12 socket The 10 100 1000 Mbit s twisted pair port all...

Page 26: ... value BB HH PP QQ Supply voltage characteristic value M9 N9 Pin Function characteristic value M9 Function characteristic value N9 Type 1 L Conductor Plus terminal of supply voltage 5 pin M12 connector K coded 2 Do not use Do not use 3 N Neutral conductor Minus terminal of supply voltage 4 Do not use Do not use 5 PE Protectiveearth connection PE Protective earth connection Table 7 Pin assignments ...

Page 27: ...pe 1 TX 4 pin M12 socket A coded 2 RX 3 4 GND Table 10 Pin assignments V 24 interface USB interface Pin Function Type 1 Uin 5 pin M12 socket A coded 2 3 D 4 GND 5 D Table 11 Pin assignments USB interface Signal contact Pin Function Type 1 Not used 5 pin M12 connector A coded 2 NO Normally open contact 3 NC Normally closed contact 4 Not used 5 CO Changeover contact Table 12 Pin assignments Signal c...

Page 28: ...vice Figure 2 Device status location of the display elements on the device front side of the device LED Display Color Activity Meaning Power Supply voltage none Supply voltage is too low yellow lights up Device variants with redundant power supply Supply voltage 1 or 2 is on flashes4times a period Software update is running Maintain the power supply green lights up Device variants with redundant p...

Page 29: ...rom the boot parameters saved Start the device again flashes4times a period Device has detected a multiple IP address RM Ring Manager none No redundancy configured green lights up Redundancy exists flashes 1 time a period Device is reporting an incorrect configuration of the RM function yellow lights up No redundancy exists ACA Storage medium ACA none ACA storage medium not connected green lights ...

Page 30: ...ssing link green lights up Device detects a valid link flashes 1 time a period Port is switched to stand by flashes 3 times a period Port is switched off yellow lights up Device detects a data rate that is not supported flashing Device is transmitting and or receiving data flashes 1 time a period Device detects at least one unauthorized MAC address Port Security Violation flashes 3 times a period ...

Page 31: ...display elements on the device front side of the device LED Display Color Activity Meaning PoE PoE status none No powered device connected green lights up Powered device is supplied with PoE voltage yellow flashes 1 time a period Output budget has been exceeded Device has detected a connected powered device flashes 3 times a period PoE administrator status deactivated Table 15 PoE status PoE ...

Page 32: ...B interface This interface is a 5 pin A coded M12 socket with shielding The USB interface allows you to connect the AutoConfiguration Adapter ACA22 M12 EEC storage medium This is used for saving loading the configuration data and diagnostic information and for loading the software The USB interface has the following properties Supplies current of max 500 mA Supports the USB master mode Supports US...

Page 33: ...ee figure 5 The signal contact allows you to control external devices or monitor device functions In the configuration you specify how the device uses the signal contact You find detailed information on possible applications and the configuration of the signal contact in the software user documentation You find the software user documentation available as download on the Internet at https www doc ...

Page 34: ...s for transport damage 2 2 Installing and grounding the device When you are selecting the installation location make sure you observe the climatic threshold values specified in the technical data Prevent heat from the surroundings from affecting the device Verify that there is at least 4 in 10 cm of space around the device Remove the provided transport protection caps and the transport protection ...

Page 35: ...ions for mounting the device in the chapter Dimension drawings on page 50 Install the device with screws on a flat metal surface Completely screw the device to the flat surface using screws through each mounting hole Exclusively use screws suitable for the installation and application case to ensure flawless operation of the device ...

Page 36: ...6 Ground the device via the ground screw You find the prescribed tightening torque in table Ground connection on page 48 Note Depending on the characteristic value of the supply voltage the device either has connections for functional ground or protective ground WARNING ELECTRIC SHOCK Ground the device before connecting any other cables Failure to follow these instructions can result in death seri...

Page 37: ...es with power supply characteristic value PP Insert the power supply cable through each ferrite 1 time Place the ferrites between the external front end power supply unit and the power supply input of the device max 19 7 in 50 cm distance from the power supply input of the device or the output of the external front end power supply unit See figure 37 Connecting the ferrites Installation of the fer...

Page 38: ...galvanic isolation Hirschmann has tested the power supply unit PC150 110V 54V and recommends its use You find the order number for the power supply unit which is available as accessory under Accessories on page 57 Note For use cases according to EN 50155 exclusively use external front end power supply units of type PC150 110V 54V or else the suitability of the device for this use case is void WARN...

Page 39: ...ing to EN 50121 4 and marine applications See Electromagnetic compatibility EMC on page 53 Connect the data cables according to your requirements See Ethernet ports on page 25 Seal all unused connections and ports with protection screws Note To sustain the IP65 67 suitability for your device seal all unused connections and ports with the provided plastic protection screws See Scope of delivery on ...

Page 40: ...4 interface Configuration via BOOTP Configuration via DHCP Option 82 You will find more information in the Basic Configuration User Manual 3 1 Default settings Ethernet ports link status is not evaluated signal contact IP address The device looks for the IP address using DHCP Twisted pair ports Autonegotiation Management password user password public read only admin password private read write Rap...

Page 41: ...rd private The device prompts you to type in a new password Type in your new password To help increase security choose a password that contains at least 8 characters which includes upper case characters lower case characters numerical digits and special characters When you log on to the device with the Command Line Interface then the device prompts you to confirm you new password Log on to the dev...

Page 42: ... maximum ambient air temperature exclusively See General data on page 45 The ambient air temperature is the temperature of the air at a distance of 2 in 5 cm from the device It depends on the installation conditions of the device for example the distance from other devices or other objects and the output of neighboring devices ...

Page 43: ...continually working on improving and developing their software Check regularly whether there is an updated version of the software that provides you with additional benefits You find information and software downloads on the Hirschmann product pages on the Internet http www hirschmann com Depending on the pollution degree of the operating environment check regularly whether the cooling fins and su...

Page 44: ...able the supply voltage Disconnect the data cables Disconnect the power supply cable Disconnect the grounding Remove the screws WARNING ELECTRIC SHOCK Disconnect the grounding only after disconnecting all other cables Failure to follow these instructions can result in death serious injury or equipment damage ...

Page 45: ...g on a flat surface on page 35 Pollution degree 2 Degree of protection IP65 67 Table 16 General data OCTOPUS OS3 Supply voltage with the characteristic value BB Rated voltage 24 V DC Voltage range including maximum tolerances 16 8 V DC 32 V DC Connection type 5 pin L coded M12 plug Tightening torque 5 3 lb in 0 6 Nm Wire diameter AWG16 1 5 mm a a When using the supplied plug Power loss buffer 20 m...

Page 46: ...including maximum tolerances PoE 47 V DC 57 V DC PoE 53 V DC 57 V DC Connection type 5 pin L coded M12 plug Tightening torque 5 3 lb in 0 6 Nm Wire diameter AWG16 1 5 mm a a When using the supplied plug Power loss buffer 10 ms Overload current protection on the device Non replaceable fuse Back up fuse for each voltage input Nominal rating 6 3 A Characteristic slow blow Peak inrush current 3 5 A Co...

Page 47: ...ut Nominal rating max 20 A Characteristic slow blow Peak inrush current 3 5 A Connection for protective grounding See Grounding the device on page 36 Current integral I t non PoE 1 5 A s PoE 1 A s Max PoE power Nominally 60 W Table 21 Supply voltage with characteristic value M9 Supply voltage with the characteristic value N9 Rated voltage 72 V DC 110 V DC Voltage range including maximum tolerances...

Page 48: ...age variants Maximum power consumption Maximum power output OS3 30 16 16 ports all variants 24 W 80 Btu IT h OS3 30 24 24 ports all variants 30 W 103 Btu IT h OS3 40 08 8 ports all variants 20 W 67 Btu IT h OS3 40 16 16 ports all variants 26 W 88 Btu IT h OS3 40 24 24 Ports all variants 32 W 111 Btu IT h OS3 34 16 16 ports PP 155 W 83 Btu IT h OS3 34 16 16 ports M9 N9 QQ 100 W 118 Btu IT h OS3 34 ...

Page 49: ... value V standard up to 6562 ft ASL 2000 m ASL 40 F 140 F 40 C 60 C 6560 ft ASL 9842 ft ASL 2000 m ASL 3000 m ASL 40 F 131 F 40 C 55 C Devices with operating temperature characteristic value T extended up to 6562 ft ASL 2000 m ASL 40 F 158 F 40 C 70 C 6560 ft ASL 9842 ft ASL 2000 m ASL 3000 m ASL 40 F 149 F 40 C 65 C Humidity 5 100 also in condensing atmospheres Air pressure min 700 hPa 9842 ft 30...

Page 50: ...7 7 Dimension drawings Figure 8 Dimension drawings Device variants with 24 10 100 1000 Mbit s twisted pair ports R 2 5 R 0 0 9 478 18 82 mm in 188 7 40 197 5 7 78 77 2 3 04 77 2 3 04 77 2 3 04 77 2 3 04 90 3 54 79 2 3 12 8 0 31 137 5 5 41 48 5 1 91 ...

Page 51: ...e 03 08 2020 51 Figure 9 Dimension drawings Device variants with 16 10 100 1000 Mbit s twisted pair ports R 2 5 R 0 0 9 400 8 15 78 77 2 3 04 77 2 3 04 77 2 3 04 90 3 54 188 7 40 197 5 7 78 8 0 31 79 2 3 12 mm in 137 5 5 41 48 5 1 91 ...

Page 52: ...3 Release 03 08 2020 Figure 10 Dimension drawings Device variants with 8 10 100 1000 Mbit s twisted pair ports R 2 5 R 0 0 9 323 6 12 74 77 2 3 04 77 2 3 04 90 3 54 188 7 40 197 5 7 78 8 0 31 79 2 3 12 137 5 5 41 mm in 48 5 1 91 ...

Page 53: ...s A Class A Class A FCC 47 CFR Part 15 Class A Class A Class A EN 61000 6 4 Fulfilled Fulfilled Fulfilled EMV 06 Rev 2 0 Class S1 Conducted emission EN 55032 AC and DC supply connections Class A Class A Class A FCC 47 CFR Part 15 AC and DC supply connections Class A Class A Class A EN 61000 6 4 AC and DC supply connections Fulfilled Fulfilled Fulfilled EN 55032 Telecommunication connections Class ...

Page 54: ...s on vehicles c c According to EN 50155 IEC 60068 2 6 test Fc Vibration 5 Hz 8 4 Hz with 0 14 in 3 5 mm amplitude Operating 5 Hz 150 Hz Broadband noise vertical 1 0 m s rms horizontal 0 7 m s rms 8 4 Hz 200 Hz with 1 g disabled 5 Hz 150 Hz Broadband noise vertically 5 72 m s rms horizontally 3 96 m s rms IEC 60068 2 27 test Ea Shock 15 g at 11 ms vertical 30 m s 30 ms horizontal 50 m s 30 ms Table...

Page 55: ...r port Length of a twisted pair segment max 328 ft 100 m for Cat5e cable Table 30 Network range 10 100 Mbit s twisted pair port 10 100 1000 Mbit s twisted pair port Length of a twisted pair segment max 328 ft 100 m for Cat5e cable Table 31 Network range 10 100 1000 Mbit s twisted pair port ...

Page 56: ...on screw for M12 socket plastic Device variants with 8 10 100 1000 Mbit s twisted pair ports 10 Protection screw for M12 socket plastic 1 Exclusively for device variants featuring supply voltage with characteristic value BB HH PP QQ Field attachable connector for the power supply M12 L coded 1 Exclusively for device variants featuring supply voltage with characteristic value M9 or N9 Field attacha...

Page 57: ...M12 EEC 942 125 001 AutoConfiguration Adapter ACA22 M12 EEC angled 942 125 002 Field attachable connector for the power supply M12 K coded 934 935 002 Field attachable connector for the power supply M12 L coded 934 935 005 Protection screw for M12 socket metal IP65 67 25 pieces 942 057 001 Protection screw for M12 socket plastic IP65 67 25 pieces 942 057 002 Protection screw for M12 plug metal IP6...

Page 58: ...tions EMC Emission and immunity of the signaling and telecommunications apparatus Rail Trackside EN 50155 Railway applications Electronic equipment on rail vehicles EN 55032 Electromagnetic compatibility of multimedia equipment Emission Requirements EN 61000 6 2 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for industrial environments EN 61131 2 Programmable controllers Par...

Page 59: ...nn Competence Center is ahead of its competitors on three counts with its complete range of innovative services Consulting incorporates comprehensive technical advice from system evaluation through network planning to project planning Training offers you an introduction to the basics product briefing and user training with certification You find the training courses on technology and products curr...

Page 60: ......

Reviews: