46
Installation OCTOPUS OS3
Release 03 08/2020
Supply voltage with the characteristic value HH
Rated voltage
36 V DC ... 48 V DC
Voltage range including maximum
tolerances
25.2 V DC ... 60 V DC
Connection type
5-pin, “L”-coded M12 plug
Tightening torque
5.3 lb-in (0.6 Nm)
Wire diameter
AWG16 (1.5 mm²)
a
a. When using the supplied plug.
Power loss buffer
>16 ms at 48 V
Overload current protection on the device Non-replaceable fuse
Back-up fuse for each voltage input
Nominal rating:
max. 20 A
Characteristic:
slow blow
Peak inrush current
8 A
Connection for functional ground
See “Grounding the device” on page 36.
Current integral I²t
<1.5 A²s
Table 18: Supply voltage with characteristic value HH
Supply voltage with the characteristic value PP
Rated voltage
PoE
48 V DC
PoE+
54 V DC
Voltage range including maximum
tolerances
PoE
47 V DC ... 57 V DC
PoE+
53 V DC ... 57 V DC
Connection type
5-pin, “L”-coded M12 plug
Tightening torque
5.3 lb-in (0.6 Nm)
Wire diameter
AWG16 (1.5 mm²)
a
a. When using the supplied plug.
Power loss buffer
>10 ms
Overload current protection on the device Non-replaceable fuse
Back-up fuse for each voltage input
Nominal rating:
6.3 A
Characteristic:
slow blow
Peak inrush current
3.5 A
Connection for functional ground
See “Grounding the device” on page 36.
Current integral I²t
<0.4 A²s
Max. PoE power
Nominally
124 W
Table 19: Supply voltage with characteristic value PP
Supply voltage with characteristic value QQ
Rated voltage
24/36/48 V DC
Voltage range including maximum
tolerances
16.8 V DC ... 60 V DC
Connection type
5-pin, “L”-coded M12 plug
Tightening torque
5.3 lb-in (0.6 Nm)
Wire diameter
AWG16 (1.5 mm²)
a
Power loss buffer
>10 ms at 24 V
>16 ms at 48 V
Overload current protection on the device Non-replaceable fuse
Table 20: Supply voltage with characteristic value QQ
Summary of Contents for HIRSCHMANN OCTOPUS OS3
Page 60: ......