The socket housing is electrically connected to the front panel of the
device.
The V.24 interface is not electrically isolated from the supply voltage.
Figure 16: Pin assignment of the V.24 interface and the DB9 connector
Note:
You will find the order number for the terminal cable, which is
ordered separately, in the Technical Data chapter
(see page 48)
.
You will find a description of the V.24 interface in the “Basic Configuration
User Manual” on the CD-ROM.
2.4
Maintenance
When designing this device, Hirschmann was largely able to forego using
wear parts. The parts subject to wear are dimensioned to last longer than
the lifetime of the product when it is operated normally. Operate this
device according to the specifications (see
).
Relays are subject to natural wear. This wear depends on the frequency
of the switching operations. Depending on the frequency of the switching
operations, check the volume resistance of the closed relay contacts and
the switching function.
Hirschmann are continually working on improving and developing their
software. You should regularly check whether there is a new version of
the software that provides you with additional benefits. You will find
software information and downloads on the product pages of the
Hirschmann website.
Depending on the degree of pollution in the operating environment, check
at regular intervals that the ventilation slots in the device are not
obstructed.
VT 100 terminal settings
Speed
9,600 Baud
Data
8 bit
Stopbit
1 bit
Handshake
off
Parity
none