MACH 1040
Release 02 03/2013
27
Connecting the signal contact
Note:
Relevant for North America:
The tightening torque for fixing the signal contact terminal block to the
device is 3 lb in (0.34 Nm).
For every signal contact to be connected, make sure the following
requirements are met:
The lines to be connected are voltage-free.
The connected voltage is limited by a current limitation or a fuse.
Observe the electrical threshold values for signal contact
(see on
page 41 „General technical data“)
.
For every signal contact to be connected, perform the following steps:
Connect the signal contact lines with the terminal block connections.
Mount the terminal block on the device using screws.
WARNING
ELECTRIC SHOCK
Never insert sharp objects (small screwdrivers, wires, etc.) into the
connection terminals for the signal lines, and do not touch the terminals!
Failure to follow these instructions can result in death, serious injury,
or equipment damage.