GUIDE TO INSTALLATION AND OPERATION
26
| IPG-3901
•
Click Edit Presets Label to open the Presets window.
•
Double-click on a name in the Label column
•
Type a new name in the window.
•
Click OK
The text you have entered (up to 16 characters) will be appended to the label name in the selection pulldown
5.9.1 Factory
Clicking the Load Factory button will restore the card to a factory default state. Four checkboxes enable the user to
choose whether to include Card Parameters, Card Alarms, Network Settings and Presets in the restoration process
Note – Card Alarms only are reset to factory values; iControl Alarms and GSM alarms are not reset. With reference to
the Alarm Configuration panel:
Reset by Load Factory?
Yes
No
No
5.9.2 Profiles
Use
Profiles
to save or recover the entire card configuration (including user presets if desired) on an external disk, or
to copy it to another IPG-3901 card.
Click on
Profiles
to open the Profile Copy window.
Copy profile from
This line shows this IPG-3901 card, and identifies it by App server, Densité frame and slot number, card type and
firmware version.
The
Profile
column has a pulldown that allows you to select which profiles you will work with, and gives these choices:
•
All, Current, User1, User2, User3, User4, User5
Profile
Values
Default
ALL
Current configuration of the card and all presets will be copied or saved on disk
ALL
Current
Only the current configuration of the card is copied or saved on disk
User1 ...User5
Only the selected preset will be copied or saved on disk
The
Select
column includes a checkbox (preselected checked) to confirm that you want to work with the current card.