background image

7

The naming of copyrighted trademarks in this
manual, even when not specially indicated,
should not be taken to mean that these names
may be considered as free in the sense of the
trademark and tradename protection law and
hence that they may be freely used by anyone.
© 2021 Hirschmann Automation and Control
GmbH

Manuals and software are protected by copy-
right. All rights reserved. The copying, repro-
duction, translation, conversion into any elect-
ronic medium or machine scannable form is
not permitted, either in whole or in part. An
exception is the preparation of a backup copy
of the software for your own use.

The performance features described here are
binding only if they have been expressly
agreed when the contract was made. This
document was produced by Hirschmann
Automation and Control GmbH according to
the best of the company's knowledge. Hirsch-
mann reserves the right to change the con-
tents of this document without prior notice.
Hirschmann can give no guarantee in respect
of the correctness or accuracy of the informa-
tion in this document.

Hirschmann can accept no responsibility for
damages, resulting from the use of the net-
work components or the associated operating
software. In addition, we refer to the conditi-
ons of use specified in the license contract.

You can get the latest version of this manual
on the Internet at the Hirschmann product site
(www.hirschmann.com).

Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany

Note

We would point out that for reasons of simplici-
ty, these operating instructions cannot descri-
be every  conceivable problem associated with
the use of this equipment. Should you require
further information or should particular
 problems occur which are not treated in suffi-
cient detail in the operating instructions, you
can request the necessary information from
your local Hirschmann sales partner or directly
from the Hirschmann office (address: refer to
chapter entitled ”Notes on CE identification“).

Safety Instructions

This manual contains instructions which must
be observed to ensure your own personal
safety and to avoid damage to devices and
machinery. The instructions are highlighted
with a warning triangle and are shown as fol -
 lows  according to the degree of endangerment:

z

Danger!

means that death, serious injury or
considerable damage to property 

will

result if the appropriate safety measures
are not taken.

z

Warning!

means that death, serious injury or

considerable damage to property 

can

result if the appropriate safety measu-
res are not taken.

z

Caution!

means that light injury or damage to
property can result if the appropriate
safety measures are not taken.

Note:

is an important piece of information about the
product, how to use the product, or the relevant
 section of the documentation to which particular
attention is to be drawn. 

Staff qualification  requirements

Note: 

Qualified personnel, as understood in this
manual and in the warning signs, are persons
who are familiar with the setup, assembly,
startup, and operation of this product and are
appropriately qualified for their job. This
includes, for example, those persons who
have been:

– trained or directed or authorized to switch on

and off, to ground and to label power circuits
and devices or systems in accordance with
current safety engineering standards

– trained or directed in the care and use of

appropriate safety equipment in accordance
with the current standards of safety engi -
neering

– trained in providing first aid.

Certified usage

Please observe the following:

z

Warning!

The device may only be employed for
the purposes described in the catalog
and technical description, and only in
conjunction with external devices and
components recommended or appro -
ved by Hirschmann. The product can
only be operated correctly and safely if
it is transported, stored, installed and
assembled properly and correctly. Fur-
thermore, it must be operated and ser-
viced carefully.

General Safety Instructions

This device is electrically operated. Adhere
strictly to the safety requirements relating to
voltages applied to the device as described
in the operating instructions!

Make sure that the electrical installation
meets local or nationally applicable safety
regulations.

z

Warning!

Failure to observe the information
given in the warnings could result in
serious injury and/or major damage.
Only personnel that have received
appropriate training should operate
this device or work in its immediate
vicinity. The personnel must be fully
familiar with all of the warnings and
maintenance measures in these ope-
rating instructions.
Correct transport, storage, and
assembly as well as careful operation
and maintenance are essential in
ensuring safe and reliable operation 
of this device.

z

Warning!

Any work that may have to be per -
formed on the electrical installation
should be performed by fully  qualified
technicians only.

z

Warning!

The optical radiated power of the
com po nents used in this device does
not represent a potential health hazard
of any description under normal, fore -
seeable conditions, and it complies
with Class 1 in accordance with IEC
60825-1 (2001).

Safety Guidelines Environment

z

Warning!

The device may only be operated in
the listed ambient temperature range
at the listed relative air humidity (non-
condensing).

The installation location is to be selected so
as to ensure compliance with the climatic
limits listed in the Technical Data.

Based specifications and 
standards

The devices fulfil the following  specifications
and standards: 
– EN 61000-6-2: Generic standards – Immuni-

ty for industrial environments

– EN 55032: Information technology equip-

ment – Radio disturbance  characteristics

– IEC 60950: Safety of Information Technology

Equipment (ITE)

Notes on CE identification

7

The devices comply with the regulations
of the following European directive:

2011/65/EU and 2015/863/EU (RoHS)
Directive of the European Parliament and of
the Council on the restriction
of the use of certain hazardous substances in
electrical and electronic
equipment.

In accordance with the above-mentioned EU
directives, the EU conformity declaration will
be available to the relevant authorities at the
following address:

Hirschmann Automation and Control GmbH
Stuttgarter Strasse 45 - 51
72654 Neckartenzlingen
Germany
www.hirschmann.com

Recycling Note

,

After its use, this product has to be
processed as electronic scrap and
disposed of according to the pre -
vailing waste disposal regulations of
your community/district /country/state.

GB

Summary of Contents for 933 990-021

Page 1: ...ected terminal device or via plug in power supply Maximum transmission distance 100 m with plastic fiber 19000 m with silica optical fiber 32000 m with single mode optical fiber Bit rate DC 115 kbit s...

Page 2: ...ontage Inbetriebsetzung und Betrieb dieses Produktes vertraut sind und die ber die ihrer T tigkeit entsprechenden Qualifikationen verf gen wie z B Ausbildung oder Unterweisung bzw Berech tigung Stromk...

Page 3: ...m glich Steckerbelegung siehe Technische Daten Warnung F r den Fall dass Sie das Modul mit einer Fremdspannung betreiben Versorgen Sie das System nur mit einer Sicherheitskleinspannung nach IEC 950 I...

Page 4: ...Endger t ausgeschaltet Sind die optischen Steckverbinder am Schnitt stellenwandler OZDV 2471 P G nicht ge steckt so kann insbesondere bei hoher Um gebungshelligkeit ein rein zuf lliges Signal an den e...

Page 5: ...mit 2 1 bzw 3 2 dB Systemreserve Streckend mpfung mit 10 125 m Faser 0 5 dB km 0 bis 32000 m1 18 dB mit 50 125 m Faser 3 0 dB km 0 bis 6700 m 2 23 dB 0 bis 19000 m1 21 dB mit 62 5 125 m Faser 3 5 dB k...

Page 6: ...n Umgebungstemperatur 20 C bis 50 C Lagerungstemperatur 20 C bis 70 C Relative Luftfeuchtigkeit 10 bis 90 nicht kondensierend Masse 110 g Geh usewerkstoff Zink Druckguss Abmessungen B x H x T 56 5 x 1...

Page 7: ...ave been trained or directed or authorized to switch on and off to ground and to label power circuits and devices or systems in accordance with current safety engineering standards trained or directed...

Page 8: ...u operate the module with an external power supply only supply the system with a safety extra low voltage in accordance with IEC 950 IEC 60 950 VDE 0805 Optical fiber connection Connect the two interf...

Page 9: ...e second terminal device is switched off If the optical plug connectors of the OZDV 2471 P G interface converter are not attached it is possible that random signals will appear at the electrical outpu...

Page 10: ...tance with 2 1 3 2 dB system reserve line attenuation with fiber 10 125 m 0 5 dB km 0 to 32000 m1 18 dB with fiber 50 125 m 3 0 dB km 0 to 6700 m 2 23 dB 0 to 19000 m1 21 dB with fiber 62 5 125 m 3 5...

Page 11: ...bient temperature 20 C to 50 C Storage temperature 20 C to 70 C Relative humidity 10 to 90 non condensing Mass 110 g Housing material die cast zinc Dimensions W x H x D 56 5 x 18 x 76 mm OZDV 2471 P O...

Page 12: ...rmation une instruction ou une habi litation qui les autorisent brancher d brancher mettre la terre ou rep rer des circuits lectriques des appareils ou des syst mes conform ment aux normes actuel les...

Page 13: ...cas o le module est mis en service sous une tension externe alimenter le syst me seulement avec une basse tension de s curit conforme aux normes IEC 950 IEC 60 950 VDE 0805 Liaison par c ble du guide...

Page 14: ...eil terminal est d branch Si les connecteurs enfichables optiques ne sont pas en place sur le convertisseur inter face OZDV 2471 P G un signal purement stochastique peut surgir aux sorties lectri ques...

Page 15: ...ou 3 2 dB r serve du syst me affaiblissement de propagation avec fibre de 10 125 m 0 5 dB km 0 32000 m1 18 dB avec fibre de 50 125 m 3 0 dB km 0 6700 m 2 23 dB 0 19000 m1 21 dB avec fibre de 62 5 125...

Page 16: ...es techniques Type OZDV 2471 P OZDV 2471 G Protection CEM Emission de parasites conforme EN 55032 classe de valeur limite B R sistance aux parasites conforme EN 61000 6 2 Conditions ambiantes climati...

Reviews: