TopWinder
®
1MANUL755
Belanger, Inc.® * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681
51
Maintenance
Torque Plate and Electric Motor Replacement
Note:
The wiring to each Motor must be removed in order to gain access to the bottom of the
Gearbox. There you can inspect and change the flat head bolts used to mount the Torque
Plate.
DANGER
DISCONNECT MAIN POWER SUPPLY PRIOR TO SERVICING
OR MAINTAINING EQUIPMENT
Remove Motor Gearbox Assembly
1) Turn off the power and place the disconnects in the OFF position.
Note:
To ensure safety we recommend following the Lock-out procedure stated above for the
main panel prior to servicing the equipment.
2) Remove the plastic Cover from the Cover Base by removing the (2) Phillips head screws. See
the image below.
Note:
Removing the Cover will allow access to the Motor Gearbox mounted on the Torque
Studs.
3) Check the voltage at the Junction Box with a multi-meter to ensure all power has been properly
removed from the circuit and no power is being supplied to the equipment.
4) Remove the Junction Box Cover to gain access to the wiring on the side of the Motor.
5) Confirm that the wiring has been tagged for terminal location if not previously identified upon
installation. Remove the nuts to release wiring from the Terminal Block. See the image below.
Remove Phillip Head Screws