61
Maintenance
Torque Plate and Electric Motor Replacement
Reinstall Motor Gearbox Assembly
15) Route the Motor Lead through the cord grip on the Motor Electrical Box.
Make sure to tighten the fitting properly to prevent any water intrusion.
16) Secure the Terminal Block back into position using the Phillips screw. See the images
below.
Note:
Be careful not to crimp or crush any of the existing wiring.
Reconnect the wiring leads to the previously tagged motor leads to maintain the
proper wiring positions.
Note:
If there are insulated ring terminals on the Terminal Block, we recommend replacing them
with non-insulated ring terminals; which can be purchased at a local hardware or 1ELECT-
FS855 can purchased through our Aftermarket Sales Department.
Note:
The non-insulated ring terminals provide more room within the Junction Box to secure
wiring into position.
17) Replace the Electrical Box Cover.
Note:
Be careful not to crimp or crush any of the existing wiring.
18) Once the Motor Gearbox unit is properly secured into position, power can be turned back
ON.
19) Verify wheel rotation prior to running any test vehicle through the system.
20) Secure the Upper Cover onto the Motor Cover Base.