Maintenance
Troubleshooting
Problem
Solution
QuickFire® Wrap Head does not walk
up the boom
•
See initial startup section (Adjusting Limit Switch)
•
Increase pressure as needed (see Adjusting Air
Regulators)
•
See initial startup section (Adjusting Wheel Speed)
QuickFire® Wrap Head does not follow
the vehicle
•
See initial startup section (Adjusting Flow Control)
•
Increase pressure if movement is too slow, decrease
if movement is too fast
•
See initial startup section (Adjusting Sizer Limit
Switch)
Wobbling Boom or Shaft
•
Check for missing pieces or damaged cleaning
material
•
Check Bearings for wear
•
Check for bent shaft
Boom not pivoting inward
•
Confirm output is set t
o “AUTO” position
•
Verify air feeds are in the proper location
•
Confirm that air is working properly on both sides of
the air cylinder, rebuild or replace if necessary
Brush is turning too slow
•
Confirm flow control setting is all the way open
•
Confirm hydraulic unit has 1000
–
1100 PSI
•
Replace motor(s)
Note:
The pressure settings stated are for Conveyor speeds of approximately 100 vehicles per
hour. Different pressure settings may be needed to compensate for different Conveyor
speeds.