GYRO WRAP™
Signature
®
Series
1MANUL248
Belanger, Inc. * PO BOX 5470 *Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681
39
Installation
Utilities: Pneumatic, Electric or Hydraulic, and Water
Pneumatic Connections
1) Locate the four small grommets, two cord grips and the two filler strips with the grommet holes
shown in the image below.
2) Snap the grommets into the appropriate holes and secure the cord grips into the holes pointed out
in the image below.
3) Slide one end of the supplied airlines and the electrical feed hanging from the base of the arms
through the holes pointed out in the image below.
Note:
If the main air at the site is hooked up and available, manually fire the solenoid valve
to make sure that the cylinders are working properly and that the arm assemblies are
extending and retracting. You may need to temporarily set the regulators so that the
arms will pivot. The startup section will go into more details on setting the pressure
for each regulator.
Gray
Blue
Passenger
Side
Electrical
Feed
Gray
Red
Driver
Side
Electrical
Feed