Installation
Inserting the Shaft – Hydraulic Drive Only
4.) Apply anti-seize to the inside of each bearing that is on the spherical bearing assembly as shown
below.
5.) Slide the shaft up through the lower bearing and the hole in the top bearing mount plate. Then slide
the upper bearing onto the shaft in the orientation shown below. The grease fitting on the bearing
must be pointing outward and toward the exit of the bay.
Apply Anti-Seize Here
Apply Anti-Seize Here
Upper Bearing
Grease Fitting
Slot in Shaft
Bearing
Mount Plate
Shaft