Operation BDL
66
METPOINT® BDL
14.2.5.4 ModBus
Main menu
Settings
Device settings
ModBus settings
14.2.5.5 SD card
Main menu
Settings
Device settings
SD card
Reset logger data base
Main menu
Settings
Device settings
SD card
Erase SD card
Note:
Further information regarding the SD card and the replacement of the card can be found in
Chapter 13.
Here the transmission parameters
Modbus
ID, baud rate, stop bit and parity
must be set.
By setting the tick for
enable Modbus
RTU(RS485)
, Modbus will be activated.
By pressing the
set to default
button, the pre-
adjusted default values are set.
Default values: Baud rate:
19200
Stop bit:
1
Parity:
even
By pressing the
reset logger data base,
the
currently stored data are blocked from use in
the BDL. However, the data remain stored on
the SD card, and are available for external
use.
By pressing the
erase SD card
button, all of
the data are completely deleted from the SD
card.