Operation BDL
48
METPOINT® BDL
Main menu
Settings
Sensor settings
A1
Text field gas constant
The remaining text fields can be
marked in the same manner as is described here, in Chapter
Marking and setting text fields
Main menu
Settings
Sensor settings
A1
See also Chapter
12.2.2.1 Selection of the sensor type (Example type: digital sensor)
Note:
After having confirmed with
OK
,
the lettering returns to black and the values and settings are accepted.
Caution:
Reference temperature and reference pressure (setting ex works 20°C, 1000 hPa):
All the volume flow (m³/h) and consumption values (m³) that are indicated on the display refer to 20°C
and 1000 hPa (according to ISO 1217 suction condition).
Alternatively, 0°C and 1013 hPa (=standard cubic metre according to DIN 1343) can also be entered
as the reference. Under no circumstances must the operating pressure or the operating temperature
be entered into the reference
conditions!
A preset selection of suitable
gas constants
.
The text fields with red letters show that
different values, such as the
diameter
and
the
name
,
were changed or added.
The three parameters flow rate, consump-
tion, and velocity are recorded (green tick),
after the data logger was activated.