6.5.29 Reset configuration to Timer factory
defaults: r5Et dEF
When the BA377E-SS is configured as a Timer this
function resets the instrument to the Timer factory
defaults shown in sections 6.5
To reset the configuration select
r5Et dEF
from the
configuration menu and press
(
. The BA377E-SS
will display
0000
with the first digit flashing which is a
request to confirm the instruction by entering
5urE
.
Using the
*
or
&
button set the first flashing digit
to
5
and press
(
to transfer control to the second
digit which should be set to
u
. When
5urE
has been
entered pressing the
)
button will reset all the
configuration functions and return the instrument to
the display mode.
Note:
r5Et dEF
does not reset the grand total to
zero.
7.
TIMER APPLICATION EXAMPLES
This section illustrates two common applications for
the BA377E-SS when configured as a Timer.
7.1
Measuring the time that a contact is
closed.
In this example a BA377E-SS is required to display
the time that a hazardous area contact is closed.
The display is required in hours and minutes within
the hazardous area and is to be reset to zero by a
push button located in the same hazardous area, not
by the instrument front panel push buttons. The
operator is required to zero the grand total by
operating the
)
and
*
buttons simultaneously.
No security codes are required to protect access to
the configuration menu or to the grand total reset.
When power is restored after a supply interruption
the Timer is to resume normal operation without
manual intervention.
Figure 18 shows the wiring for the BA377E-SS when
powered by a single channel Zener barrier.
Fig 18 Wiring for displaying time a contact is closed
The required instrument configurations for this
example are shown below.
Function
Display
Setting
Access code
CodE
0000
Function
FunCtion
ELAP5E
Input
inPut
ContACt
Terminals 3 & 4 linked to energise input
Debounce
dEbounCE
dEFAuLt
Display 2
di5P-2
oFF
Start stop
5tAr5toP
ControL 2
Units
unit5
12 : 00
Set time
5Et t
9999
:
99
:
99
Direction of count
up or dn
up
Power fail
p-fail
continue
Local reset
loc r5et
Local total reset
rE5E EnbL
oFF
Local grand total reset
Clr Gtot
on
Summary of Contents for BA377E-SS
Page 1: ...Issue 6 4th May 2021 BA377E SS Rugged one input intrinsically safe Timer or Clock Issue 6...
Page 30: ...30...
Page 31: ...31...
Page 42: ...42...
Page 54: ...54...
Page 55: ...55...
Page 56: ...56...
Page 57: ...57...
Page 58: ...58...
Page 59: ...59...
Page 60: ...60...
Page 61: ...61...
Page 62: ...62...
Page 63: ...63...
Page 64: ...64...
Page 65: ...65...