21
6.2
Controls when configured as a Timer
The BA377E-SS is controlled and configured via four
front panel push buttons. In the display mode i.e.
when the instrument is displaying time the push
button functions are:
Push Button Functions
&
When local control is enabled starts
the Timer. See 6.5.8
*
When local control is enabled stops
the Timer. See 6.5.8
)
+
*
Shows the grand total (run time) in
hours and tenths of an hour
irrespective of Timer configuration.
If buttons are held for longer than
ten seconds the grand total may be
reset to zero if the grand total reset
sub-function
clr gtot
is enabled in
the
LoC r5Et
configuration function.
See 6.5.20
To reset the grand total to zero from
the display mode press the
)
+
*
buttons for ten seconds until
CLr. no
is displayed, using the
&
or
*
button change the display to
CLr.
YE5
and press
)
.
&
+
*
Resets the Timer to zero or to the
set time
5Et t
depending on
whether the Timer is configured to
time-up
or
time-down
when the two
buttons
are
operated
simultaneously for more than three
seconds. This is a configurable
function. See 6.5.19
(
+
*
When enabled in the configuration
menu, operating these two buttons
simultaneously provides direct
access to the set time
5Et t
and
allows adjustment when the timer is
in the display mode. See 6.5.15
(
+
&
Shows in succession, firmware
version number, instrument function
elap5e
and any output accessories
that are fitted:
-A
Dual Control Outputs
(
+
)
Access to configuration menu
6.3
Displays when configured as a Timer
The BA377E-SS has two digital displays and
associated annunciators as shown on page 1.
Elapsed time
The upper display shows the
elapsed time since the Timer
was started when
timing-up
from
zero and the remaining time
when
timing-down
from the set
time. The display may be
formatted as hh:mm:ss; hh:mm;
mm:ss or ss.
Lower display
The display options available on
the lower display depend on
whether the Timer repeat cycle
function
CYCLE5
, which can
repeat the timing period up to 99
times, or continuously with a
configurable delay between
periods, is enabled.
CYCLE5
disabled
The lower display shows the set
time
5ET t
, or the lower display
may be disabled if not required.
See 6.5.7
CYCLE5
enabled
The lower display shows the
total number of repeat cycles
requested together with the
number of the current cycle.
Each operation may be briefly
named at it's start or periodically
throughout the cycle.
The lower display may also be
disabled if not required.
See 6.5.7
Reset
Activated while elapsed time is
annunciator
being reset to zero or to the set
time
5ET t
.
Grand total
Activated when the grand total
annunciator
time is being shown on the upper
display.
Control output
Show status of both optional
annunciators
control outputs.
Summary of Contents for BA377E-SS
Page 1: ...Issue 6 4th May 2021 BA377E SS Rugged one input intrinsically safe Timer or Clock Issue 6...
Page 30: ...30...
Page 31: ...31...
Page 42: ...42...
Page 54: ...54...
Page 55: ...55...
Page 56: ...56...
Page 57: ...57...
Page 58: ...58...
Page 59: ...59...
Page 60: ...60...
Page 61: ...61...
Page 62: ...62...
Page 63: ...63...
Page 64: ...64...
Page 65: ...65...