9.3.12 Flash display when alarm occurs:
FL5H
In addition to the two alarm annunciators on the left
hand side of the Counter display which show the
status of both alarms, this function provides an even
more conspicuous indication that an alarm condition
has occurred.
When enabled, this function alternates the rate or
total display between the numerical value and the
alarm identification
AL1
or
AL2
when an alarm
occurs.
Using the
&
or
*
push button select
FL5H
from the
selected alarm sub-menu and press
(
to check or
change the function. The
&
or
*
push button will
toggle the function between
oFF
and
on
, when set as
required, press the
)
button to return to the
FL5H
prompt in the alarm sub-menu.
9.3.13 Access Setpoint:
AC5P
This function activates a separate menu that
provides direct access to the alarm setpoints from
the display mode, i.e. when the BA367NE is
counting, by simultaneously operating the
(
and
*
buttons. An operator can therefore adjust the
alarm setpoints without having access to the
configuration and alarm sub-menus. Protection
against unauthorised or accidental adjustment is
provided by a separate security access code.
Using the
&
or
*
push button select
AC5P
from the
configuration menu and press
(
to reach the
enable function
EnbL
. Pressing
(
will reveal the
existing setting which can be toggled between
on
and
oFF
by pressing the
&
or
*
push button.
When set as required, press the
)
button to return
to the
EnbL
prompt from which a separate security
access code can be entered using the
ACCd
function
which can be selected using the
&
or
*
push
button.
To enter a new security code select
ACCd
from the
AC5P
sub-menu and press
(
which will cause the
Counter to display
0000
with one digit flashing. The
flashing digit may be adjusted using the
&
or
*
push button, when set as required operating the
(
button will transfer control to the next digit.
When all the digits have been adjusted press
)
twice to return to the
AC5p
prompt in the
configuration menu. The revised security code will
be activated when the Counter is returned to the
display mode. Default security access code
0000
will disable the security code allowing direct access
to the setpoints from the totalisation mode by
pressing the
(
and
*
buttons simultaneously.
Please contact BEKA associates sales department if
the security code is lost.
9.3.14 Adjusting alarm setpoints from the
totalisation mode
Access to the two alarm setpoints from the Counter
display mode is obtained by operating the
(
and
*
push buttons simultaneously as shown in Fig 15.
If the setpoints are not protected by a security code
the alarm setpoint prompt
5P1r
or
5P1t
will be
displayed depending upon whether a rate or total
alarm has been conditioned. If access to the
setpoints is protected by a security code,
CodE
will
be displayed first. Pressing
(
again will allow the
alarm setpoint security code to be entered digit by
digit using the
&
or
*
button to change the
flashing digit and the
(
push button to move control
to the next digit. If the correct code is entered
pressing
)
will result in the alarm setpoint prompt
5P1
x to be displayed. If an incorrect security code is
entered, or a button is not pressed within ten
seconds, the instrument will automatically return to
the totalisation mode.
Once within the menu pressing the
&
or
*
buttons
will toggle the display between the two alarm
setpoint prompts
5P1
x and
5P2
x.
Fig
15 Setpoint
adjustment
from
the totalisation mode
32
Summary of Contents for BA364G
Page 1: ...Issue 7 9th July 2019 BA367NE One input Ex nA and Ex tc Counter Issue 7 ...
Page 16: ...16 ...
Page 17: ...17 ...