89
Up
and
Down
push-buttons, and the
P
button to
transfer control to the next digit. When the
required code has been entered press
E
to return
to the main menu. The revised security code will
be activated when the clock is returned to the
display mode.
If the security code is lost, access to the
programmable functions can be obtained by
moving the internal security link to the override
position. The original security code can then be
viewed by selecting ‘COdE’ from the main menu
and pressing
P.
Section 1.6.1 explains how to
move the link.
5.5.7 Control output enable: ‘EnbL’
This function, which appears in each of the two
control output sub menus OP1 and OP2,
determines whether the output turns on and off,
once or twice every twenty four hours.
To check or change the function select 'EnbL'
from the required control output menu and press
P
which will reveal the current setting. Pressing
the
Up
or
Down
button will scroll through the
three options:
Display
Control output
’OFF’
Control output disabled
‘On:1’ Turns on & off once per 24 hours
‘On:2’ Turns on & off twice per 24 hours
5.5.8 Setpoint times: ‘OP1’
Each of the two control outputs has two or four
setpoints depending upon whether the output has
been programmed to turn on & off once or twice
in each 24 hour period. – see 5.5.7
To adjust the setpoints of control output 1 select
'OP1' from the main menu and press
P
which will
will cause the ‘EnbL’ prompt to be displayed.
Pressing the
Up
button will scroll through the
setpoints. There will only be two setpoints if the
control output has been conditioned to switch on
& off once.
Display
Setpoint
’OP1 : On1’
Time OP1 turns on first time
‘OP1 : OFF1’
Time OP1 turns off first time
‘OP1 : On2’
Time OP1 turns on second time
‘OP1 : OFF2’
Time OP1 turns off second time
When the required setpoint is displayed press
P
to reveal the current setting. Each digit may be
adjusted using the
Up
and
Down
push-buttons.
The
P
button transfers control to the next digit.
When set as required, press
E
to return the sub-
menu from which another setpoint may be
selected.
Note:
Seconds are always displayed while the
set points are being adjusted.
5.5.9 Access Setpoint: ‘AcSP’
This function activates a separate menu that
provides direct access to the control output
setpoints when the clock is in the display mode.
See section 5.5.10 for a full description. An
operator may therefore adjust the setpoints
without having access to the programme menus.
Further protection is provided by a separate
security code.
This direct access menu is enabled and a
separate security code entered from the 'AcSP'
function in the main programme menu as shown
in Fig 5.3. To change the menu parameters
select 'AcSP' from the programme menu and
press
P
. This will display the enable prompt
'EnbL'.
Pressing
P
again will reveal if the direct access
menu is 'On' or 'OFF'. The
Up
or
Down
buttons
will toggle the display between the two
conditions.
If 'OFF' is selected, the operator will not have
direct access to the setpoints when the BA364D
clock is displaying time. Return to the 'AcSP'
prompt in the main menu by pressing
E
twice.
If 'On' is selected, the operator will have direct
access to the control output setpoints when the
BA364D is displaying time via a separate menu
and optional security code. To define this four
digit numeric code press
E
to return to the 'EnbL'
prompt followed by the
Up
or
Down
button to
select the access code prompt 'AcCd'. Pressing
P
will then reveal the current security code with
one digit flashing. The code may be changed by
operating the
Up
or
Down
push-buttons and
pressing the
P
button to transfer control to the
next digit. Finally press
E
twice to enter the new
security code and return to the 'AcSP' prompt in
the programme menu.
Entering code 0000 will disable the security code
allowing direct access to the setpoints in the
display mode by pressing the
P
and
Up
buttons
simultaneously.
New instruments with control outputs are
supplied with the security code set to 0000