Copyright © 2017 TTAAll Rights Reserved.
Appendix Implication of indicator light
39
③
After the spraying work is done,AB mode can be shut down by switching into
altitude mode.
6) To return to the breakpoint, shut down the AB mode auto-controlled or manual-
controlled. After filling the pesticide in the tank and taking off,switch SA (flight mode)to
AB mode directly ,the drone would return right to the breakpoint.
2. Remove Point A and B
Struck SD (AB mode) for 4-5 times rapidly,LED alternately flash red green and yellow,AB
mode removed.
Without removing last AB point,can not set new AB point.
3. Set the Interval Width
From the software->plant protect function
to set the spraying width and working speed
Attention:
1) Be sure to start AB mode within turning on the pump and agitation function working.
2) Be sure it is at least 10 meters away from point A to point be.
3) Every time recording point A and B,be sure to wait until the drone self-hovering
steadily in GPS mode.
4) Without removing last AB point,can not set new AB point.
5.3.1.2 Traverse Mode
Traverse mode assist to work,move rightwards or leftwards for one spraying width.To
assist AB mode finish spraying irregular shaped field
5.3.2 Control of the Pump
1) Instruction of controlling the pump