6
Safety features
The heater will switch off automatically if the ambient temperature exceeds 70ºC (158ºF).
When using the temperature mode, the heater will switch off automatically if the rate of
temperature rise is too low.
On models equipped with a swing arm, the arm can be fixed in the open position.
An induction heater works due a magnetic field. In the table below are there are some measured
values of the flux density in milliTesla (mT). These values are measured in different radii and heights
around the heater. These measurements can be used as a guide in conforming to local regulations
regarding the maximum time exposure of people to magnetic fields.
The values below are only valid for this combination of bearing type and yoke bar.
Different configurations may give different values. Due to the large variety of bearing types in
combination with the different yoke bars it is impossible for us to give every possible value.
Heater type
Radius/height
h = 250 mm
(10in)
h = 500 mm
(20in)
h = 750 mm
(30in)
h =1000 mm
40in)
h = 1250 mm
(49in)
Model 22ELDi
Yoke bar 40
Bearing 6215
R =250 mm
0,785 mT
0,110 mT
0 mT
0 mT
0 mT
R =500 mm
0,054 mT
0,012 mT
0 mT
0 mT
0 mT
R =750 mm
0 mT
0 mT
0 mT
0 mT
0 mT
R =1000 mm
0 mT
0 mT
0 mT
0 mT
0 mT
Model 22ESDi
Yoke bar 60
Bearing 6219
R =250 mm
2,950 mT
1,070 mT
0,120 mT
0 mT
0 mT
R =500 mm
0,310 mT
0,170 mT
0,050 mT
0 mT
0 mT
R =750 mm
0,500 mT
0,250 mT
0 mT
0 mT
0 mT
R =1000 mm
00 mT
00 mT
0 mT
0 mT
0 mT
Model 38ESD
Yoke bar 70
Bearing 6222
R =250 mm
6,800 mT
4,310 mT
0,590 mT
0,110 mT
0 mT
R =500 mm
0,935 mT
0,696 mT
0,230 mT
0,042 mT
0 mT
R =750 mm
0,204 mT
0,152 mT
0,059 mT
0 mT
0 mT
R =1000 mm
0,034 mT
0,023 mT
0,003 mT
0 mT
0 mT
R =1250 mm
0 mT
0 mT
0 mT
0 mT
0 mT
Heater type
Radius/height
*
h = 900 mm
(10in)
h=1300 mm
(51in)
h=1500 mm
(59in)
h =2000 mm
(79in)
Model 38ZFD
Yoke bar 80
Bearing
229750/03
R =250 mm
5,800 mT
0,750 mT
0,253 mT
0,010 mT
R =500 mm
1,070 mT
0,320 mT
0,134 mT
0 mT
R =750 mm
0,345 mT
0,141 mT
0,068 mT
0 mT
R =1000 mm
0,121 mT
0,054 mT
0,020 mT
0 mT
R =1250 mm
0,030 mT
0,006 mT
0 mT
0 mT
Model SUPER
Yoke bar 100
Bearing RH24B
R =250 mm
6,400 mT
4,100 mT
1,460 mT
0,150 mT
R =500 mm
1,308 mT
1,050 mT
0,530 mT
0,105 mT
R =750 mm
0,350 mT
0,298 mT
0,186 mT
0,037 mT
R =1000 mm
0,116 mT
0,093 mT
0,063 mT
0,010 mT
R =1250 mm
0,030 mT
0,017 mT
0,010 mT
0 mT
Model GIANT
Yoke bar 150
Bearing
17.52926
R =500 mm
1,980 mT
1,375 mT
1,020 mT
0,340 mT
R =750 mm
0,530 mT
0,450 mT
0,370 mT
0,170 mT
R =1000 mm
0,180 mT
0,180 mT
0,160 mT
0,080 mT
R =1250 mm
0,070 mT
0,030 mT
0,030 mT
0,030 mT
R =1500 mm
0,020 mT
0,020 mT
0,010 mT
0 mT
R =1750 mm
0 mT
0 mT
0 mT
0 mT
Heights are measured from the bottom of the heater. To determine where the field is exactly in relation
to the floor, the distance from the bottom of the heater to the floor should be added on to the values
mentioned in the table. (e.g. the height of a workbench).
WARNING!
We advise a safety distance of at least 1 meter for people.
CAUTION!
The machine works through an induction field. Bear in mind that this can influence
electronic equipment, e.g. watches, magnetic charts etc.
Summary of Contents for BETEX 22 ELDi
Page 2: ......
Page 15: ...15 9 TECHNICAL DATA ...
Page 18: ...18 ...
Page 30: ...30 9 Technische Daten ...
Page 44: ...44 9 Datos téchnicos ...
Page 58: ...58 9 Information techniques ...
Page 72: ...72 9 Technische gegevens ...
Page 75: ...75 Appendix 1 Electrical diagrams BETEX 22 ELDi BETEX 22 ESDi ...
Page 76: ...76 BETEX 24 RLDi 24 RSDi BETEX 38 ESD 40 RSD ...
Page 77: ...77 BETEX 38 ZFD BETEX 40 RMD ...
Page 78: ...78 BETEX SUPER BETEX GIANT 40 kVA BETEX GIANT 48 kVA ...
Page 79: ...79 ...