background image

Foreword

EL3182

10

Version: 1.2

Fig. 5: EP1258-00001 IP67 EtherCAT Box with batch number/ date code 22090101 and unique serial
number 158102

Fig. 6: EP1908-0002 IP67 EtherCAT Safety Box with batch number/ date code 071201FF and unique serial
number 00346070

Fig. 7: EL2904 IP20 safety terminal with batch number/ date code 50110302 and unique serial number
00331701

Fig. 8: ELM3604-0002 terminal with unique ID number (QR code) 100001051 and serial/ batch number
44160201

Summary of Contents for EL3182

Page 1: ...Documentation EL3182 2 Channel Analog Input Terminal 4 20 mA single ended 16 bit HART 1 2 2018 01 30 Version Date...

Page 2: ......

Page 3: ...nstallation instructions for enhanced mechanical load capacity 29 4 4 Connection 30 4 4 1 Connection system 30 4 4 2 Wiring 32 4 4 3 Shielding 33 4 5 Installation positions 33 4 6 Positioning of passi...

Page 4: ...NAMUR basic information 117 6 HART 118 6 1 Setting 118 6 2 Slave Information 118 6 3 Measured values 119 6 4 Acyclic services 120 7 Field Device Tool FDT 122 7 1 Application via TwinCAT FDT 122 7 2 U...

Page 5: ...ion of products that have already been supplied may be made on the basis of the data diagrams and descriptions in this documentation Trademarks Beckhoff TwinCAT EtherCAT EtherCAT G EtherCAT G10 EtherC...

Page 6: ...ined specialists in control automation and drive engineering who are familiar with the applicable national standards Description of instructions In this documentation the following instructions are us...

Page 7: ...4 0000 is the order identifier in the case of 0000 usually abbreviated to EL3314 0016 is the EtherCAT revision The order identifier is made up of family key EL EP CU ES KL CX etc type 3314 version 000...

Page 8: ...he following syntax can be used see respective device documentation Syntax D ww yy x y z u D prefix designation ww calendar week yy year x firmware version of the bus PCB y hardware version of the bus...

Page 9: ...Version 1 2 Fig 2 EK1100 EtherCAT coupler standard IP20 IO device with serial batch number Fig 3 CU2016 switch with serial batch number Fig 4 EL3202 0020 with serial batch number 26131006 and unique...

Page 10: ...r 158102 Fig 6 EP1908 0002 IP67 EtherCAT Safety Box with batch number date code 071201FF and unique serial number 00346070 Fig 7 EL2904 IP20 safety terminal with batch number date code 50110302 and un...

Page 11: ...product it can be found in the following places on the packaging unit directly on the product if space suffices on the packaging unit and the product The BIC is machine readable and contains informat...

Page 12: ...s are used by Beckhoff and serve internal processes Structure of the BIC Example of composite information from item 1 to 4 and 6 The data identifiers are marked in red for better display BTN An import...

Page 13: ...protocol enables two way communication through digital data transfer via the analog 4 20 mA wiring The advantages of the simple and robust 4 20 mA interface are combined with the diagnostic and param...

Page 14: ...e Activatable FIR IIR filters Limit value monitoring ExtendedRange 107 NE43 NAMUR Max allowed output current Uv1 Uv2 typ 150 mA per connector Weight approx 60 g Permissible ambient temperature range d...

Page 15: ...802 3 Pin Color of conductor Signal Description 1 yellow TD Transmission Data 2 orange TD Transmission Data 3 white RD Receiver Data 6 blue RD Receiver Data Due to automatic cable detection auto cross...

Page 16: ...l for longer than the set and activated SM watchdog time e g in the event of a line interruption the watchdog is triggered and the outputs are set to FALSE The OP state of the terminal is unaffected T...

Page 17: ...the checkbox is not activated nothing is downloaded and the ESC settings remain unchanged Multiplier Multiplier Both watchdogs receive their pulses from the local terminal cycle divided by the watchdo...

Page 18: ...witching off of the SM watchdog via SM watchdog 0 is only implemented in terminals from version 0016 In previous versions this operating mode should not be used CAUTION Damage of devices and undefined...

Page 19: ...tional Safe Op During transition between Pre Op and Safe Op the EtherCAT slave checks whether the sync manager channels for process data communication and if required the distributed clocks settings a...

Page 20: ...ation values for analog measurement or passwords The order is specified in 2 levels via hexadecimal numbering main index followed by subindex The value ranges are Index 0x0000 0xFFFF 0 65535dez SubInd...

Page 21: ...ters are still available after a restart The situation may be different with other manufacturers An EEPROM is subject to a limited lifetime with respect to write operations From typically 100 000 writ...

Page 22: ...is to be stored permanently enter it in the Startup list The order of the Startup entries is usually irrelevant Fig 15 Startup list in the TwinCAT System Manager The Startup list may already contain v...

Page 23: ...The actual current slave list is read This may take several seconds depending on the size and cycle time The actual identity is displayed The firmware and hardware version of the equipment according t...

Page 24: ...placeholder n tends to be used for the individual channel numbers In the CoE system 16 indices each with 255 subindices are generally sufficient for representing all channel parameters The channel bas...

Page 25: ...1 ns Zero point 1 1 2000 00 00 Size 64 bit sufficient for the next 584 years however some EtherCAT slaves only offer 32 bit support i e the variable overflows after approx 4 2 seconds The EtherCAT mas...

Page 26: ...highly insulating materials synthetic fibers plastic film etc Surroundings working place packaging and personnel should by grounded probably when handling with the devices Each assembly must be termin...

Page 27: ...lock clicks onto the mounting rail If the terminals are clipped onto the mounting rail first and then pushed together without tongue and groove the connection will not be operational When correctly as...

Page 28: ...ents The six spring contacts of the K Bus E Bus deal with the transfer of the data and the supply of the Bus Terminal electronics The power contacts deal with the supply for the field electronics and...

Page 29: ...for testing these Power Feed Terminals can be released and pulled at least 10 mm from the group of terminals WARNING Risk of electric shock The PE power contact must not be used for other potentials...

Page 30: ...ef and the wire connection should be kept as short as possible A distance of approx 10 cm should be maintained to the cable duct 4 4 Connection 4 4 1 Connection system WARNING Risk of electric shock a...

Page 31: ...nnection wires when the connector is removed Conductor cross sections between 0 08 mm2 and 2 5 mm2 can continue to be used with the proven spring force technology The overview and nomenclature of the...

Page 32: ...t toggle 2 The wire can now be inserted into the round terminal opening without any force 3 The terminal point closes automatically when the pressure is released holding the wire securely and permanen...

Page 33: ...technical data for a terminal to ascertain whether any restrictions regarding the installa tion position and or the operating temperature range have been specified When installing high power dissi pa...

Page 34: ...in Fig Recommended distances for standard installation position is recommended Other installation positions All other installation positions are characterized by different spatial arrangement of the m...

Page 35: ...Terminals ELxxxx ESxxxx which do not take an active part in data transfer within the bus terminal block are so called passive terminals The passive terminals have no current consump tion out of the E...

Page 36: ...Mounting and wiring EL3182 36 Version 1 2 Fig 29 Incorrect positioning 4 7 LEDs and connection Fig 30 LEDs and connection EL3182...

Page 37: ...mmunication on HART communication active HART Error red HART communication error Connection assignment EL3182 Terminal point Description Designation No I1 1 Input channel 1 Uv1 2 Sensor supply interna...

Page 38: ...is GNDint potential in common the common GNDint potential A is connected for 1 and 2 channel terminals to a terminal point and not with GNDPC power contact is connected for 4 channel terminals with GN...

Page 39: ...2 is connected to 2 sensors which are supplied with 5 and 24 V Both current measurements are executed as low side measurements This connection type is permitted because at Imax CMPch1 and CMPch2 are a...

Page 40: ...t potential differences UCM 10 V applicable to EL30xx between the two channels which is not permitted Fig 35 Example 2 high side low side measurement To rectify this GNDint can in this case be connect...

Page 41: ...NDint is connected to terminal point for external connection GNDint should be connected externally such that condition 2 is met EL3xx4 GND is connected with the negative power contact The external con...

Page 42: ...ended Automation Visual Studio Integration Choice of the programming language Supports object orientated extension of IEC 61131 3 Usage of C C as programming language for real time applications Connec...

Page 43: ...s listed under Compatible devices can be assigned a driver via the Install button A driver should only be installed on compatible devices A Windows warning regarding the unsigned driver can be ignored...

Page 44: ...s of the EtherCAT device can be opened by double click on Device EtherCAT within the Solution Explorer under I O After the installation the driver appears activated in the Windows overview for the net...

Page 45: ...Commissioning EL3182 45 Version 1 2 Fig 42 Exemplary correct driver setting for the Ethernet port Other possible settings have to be avoided...

Page 46: ...Commissioning EL3182 46 Version 1 2 Fig 43 Incorrect driver settings for the Ethernet port...

Page 47: ...here an EL6601 or similar devices are used it is useful to specify a fixed IP address for this port via the Internet Protocol TCP IP driver setting and to disable DHCP In this way the delay associated...

Page 48: ...was current at the time when the TwinCAT build was created For TwinCAT 2 11 TwinCAT 3 and higher the ESI directory can be updated from the System Manager if the programming PC is connected to the Inte...

Page 49: ...on 1019 or for an older revision The ESI must then be requested from the manufacturer in this case Beckhoff b an ESI is present for the EL2521 0000 device but only in an older revision e g 1018 or 101...

Page 50: ...leted as follows close all System Manager windows restart TwinCAT in Config mode delete OnlineDescription0000 xml restart TwinCAT System Manager This file should not be visible after this procedure if...

Page 51: ...3182 51 Version 1 2 Reasons may include Structure of the xml does not correspond to the associated xsd file check your schematics Contents cannot be translated into a device description contact the fi...

Page 52: ...sence of the actual I O environment drives terminals EJ modules If the configuration is to be prepared in advance of the system configuration as a programming system e g on a laptop this is only possi...

Page 53: ...ion 63 can also be carried out for comparison 5 1 5 OFFLINE configuration creation Creating the EtherCAT device Create an EtherCAT device in an empty System Manager window Fig 53 Append EtherCAT devic...

Page 54: ...can be appended by right clicking on a device in the configuration tree Fig 57 Appending EtherCAT devices left TwinCAT 2 right TwinCAT 3 The dialog for selecting a new device opens Only devices for w...

Page 55: ...ion can be displayed as Extended Information Fig 59 Display of device revision In many cases several device revisions were created for historic or functional reasons e g through technological advancem...

Page 56: ...This also enables subsequent replacement of devices without changing the configuration different specifications are possible for drives Example If an EL2521 0025 1018 is specified in the configuration...

Page 57: ...Commissioning EL3182 57 Version 1 2 Fig 62 EtherCAT terminal in the TwinCAT tree left TwinCAT 2 right TwinCAT 3...

Page 58: ...online search is not available in RUN mode production operation Note the differentiation be tween TwinCAT programming system and TwinCAT target system The TwinCAT 2 icon or TwinCAT 3 icon within the W...

Page 59: ...e respective devices are lo cated in the stored ESI data and integrated in the configuration tree in the default state defined there Fig 67 Example default state NOTE Slave scanning in practice in ser...

Page 60: ...figuration B tsm in order to check the built machine However if the series machine production department now doesn t use B tsm but instead carries out a scan to create the productive configuration the...

Page 61: ...hed to online state OPERATIONAL Fig 73 Config FreeRun query left TwinCAT 2 right TwinCAT 3 In Config FreeRun mode the System Manager display alternates between blue and red and the EtherCAT device con...

Page 62: ...ce is detected i e an EtherCAT slave for which no ESI XML description is available In this case the System Manager offers to read any ESI that may be stored in the device This case is described in the...

Page 63: ...guration is then replaced by the revision found this can affect the supported process data and functions If a scan is initiated for an existing configuration the actual I O environment may match the c...

Page 64: ...sed on the higher revision number Device selection based on revision compatibility The ESI description also defines the process image the communication type between master and slave device and the dev...

Page 65: ...offers a function Change to Compatible Type for the exchange of a device whilst retaining the links in the task Fig 82 Dialog Change to Compatible Type left TwinCAT 2 right TwinCAT 3 This function is...

Page 66: ...s are now available for configuring the terminal And yet the dimension of complexity of a subscriber determines which tabs are provided Thus as illustrated in the example above the terminal EL3751 pro...

Page 67: ...the start up phase Tick the control box to the left of the input field in order to modify the default value Previous Port Name and port of the EtherCAT device to which this device is connected If it...

Page 68: ...difications include mask out a channel displaying additional cyclic information 16 bit display instead of 8 bit data size etc In so called intelligent EtherCAT devices the process data information is...

Page 69: ...incorrect configuration the EtherCAT slave usu ally refuses to start and change to OP state The System Manager displays an invalid SM cfg log ger message This error message invalid SM IN cfg or invali...

Page 70: ...t to the mailbox Move Up This button moves the selected request up by one position in the list Move Down This button moves the selected request down by one position in the list New This button adds a...

Page 71: ...ct can be read but no data can be written to the object read only P An additional P identifies the object as a process data object Value Value of the object Update List The Update list button updates...

Page 72: ...cts included in the object list of the slave is uploaded from the slave via SDO information The list below can be used to specify which object types are to be uploaded Offline via EDS File If this opt...

Page 73: ...ain Current State Indicates the current state of the EtherCAT device Requested State Indicates the state requested for the EtherCAT device DLL Status Indicates the DLL status data link layer status of...

Page 74: ...is deactivated not selected and greyed out this indicates that the input is excluded from the PDO assignment In order to be able to select a greyed out PDO the currently selected PDO has to be desele...

Page 75: ...riefly deals with a number of aspects of EtherCAT Slave operation under TwinCAT More detailed information on this may be found in the corresponding sections of for instance the EtherCAT System Documen...

Page 76: ...EtherCAT Master updated in every cycle red Output variables from the Slave to the EtherCAT Master updated in every cycle green Information variables for the EtherCAT Master that are updated acyclicall...

Page 77: ...on This may possibly have effects on the process data of other Slaves that are located in the same Syn cUnit In order for the higher level PLC task or cor responding control applications to be able to...

Page 78: ...cally in the slave depends on the device EL terminals except the EL66xx are able to save in this way The user must manage the changes to the StartUp list Commissioning aid in the TwinCAT System Manage...

Page 79: ...operation After the operating power is switched on an EtherCAT Slave must go through the following statuses INIT PREOP SAFEOP OP to ensure sound operation The EtherCAT Master directs these statuses in...

Page 80: ...t as standard EtherCAT Master OP Slaves OP This setting applies equally to all Slaves Fig 98 Default behaviour of the System Manager In addition the target state of any particular Slave can be set in...

Page 81: ...e Fig 100 PLC function blocks Note regarding E Bus current EL ES terminals are placed on the DIN rail at a coupler on the terminal strand A Bus Coupler can supply the EL terminals added to it with the...

Page 82: ...ve a warning message E Bus Power of Terminal is output in the logger window when such a configuration is activated Fig 102 Warning message for exceeding E Bus current NOTE Caution Malfunction possible...

Page 83: ...espective object or via the Process Data tab 67 allocation of PDOs Please note the following general CoE notes 20 when using manipulating the CoE parameters Keep a startup list if components have to b...

Page 84: ...0x00 0dez 80n0 11 User scale offset User scaling offset INT16 RW 0x0000 0dez 80n0 12 User scale gain User scaling gain The gain is represented in fixed point format with the factor 2 16 The value 1 co...

Page 85: ...RW Dependent on 80nD 11 80nD 18 High Range Error Upper threshold for setting the error bit and error led INT32 RW Dependent on 80nD 11 Index 0x80n0 HART Settings n 8 Channel 1 n 9 Channel 2 Index hex...

Page 86: ...ror The error bit is set if the data is invalid over range under range BOOLEAN RO 0x00 0dez 60n0 0E Sync error The Sync error bit is only required for DC mode It indicates whether a synchronization er...

Page 87: ...rticular device UINT8 RO 0x00 0dez 90n0 07 PhysicalSign alingCode Allowed values UINT8 RO 0x00 0dez 0 Bell 202 Current 1 Bell 202 Voltage 2 RS 485 3 RS 232 4 Wireless 6 Special 90n0 08 Flags HART Flag...

Page 88: ...nt state of the slave UINT8 RO 0x00 0dez 60n0 02 Cyclic Frame Cnt Cyclic Frame Counter UINT8 RO 0x00 0dez 60n0 05 Primary Variable Units Code Primary Variable Units Code refer to HART Common Table Spe...

Page 89: ...Default 1000 0 Device type Device type of the EtherCAT slave the Lo Word contains the CoE profile used 5001 The Hi Word contains the module profile according to the modular device profile UINT32 RO 0x...

Page 90: ...c Index 0x10F0 Backup parameter handling Index hex Name Meaning Data type Flags Default 10F0 0 Backup parameter handling Information for standardized loading and saving of backup entries UINT8 RO 0x01...

Page 91: ...bIndex 005 5 PDO Mapping entry object 0x6000 AI Inputs entry 0x07 Error UINT32 RO 0x6000 07 1 1A0n 06 SubIndex 006 6 PDO Mapping entry 1 bits align UINT32 RO 0x0000 00 1 1A0n 07 SubIndex 007 7 PDO Map...

Page 92: ...Cmd3 entry 0x08 Quaternary Variable Units Code UINT32 RO 0x6080 08 8 1A1n 08 SubIndex 008 8 PDO Mapping entry object 0x6080 HART Cmd3 entry 0x09 Primary Variable Loop Current UINT32 RO 0x6080 09 32 1A...

Page 93: ...5dez 1C13 01 SubIndex 001 1 allocated TxPDO contains the index of the associated TxPDO mapping object UINT16 RW 0x1A00 6656dez 1C13 02 SubIndex 002 2 allocated TxPDO contains the index of the associat...

Page 94: ...Commissioning EL3182 94 Version 1 2 Index 0x1C32 SM output parameter...

Page 95: ...rted Bit 2 3 01 DC mode is supported Bit 4 5 10 Output shift with SYNC1 event only DC mode Bit 14 1 dynamic times measurement through writing of 0x1C32 08 UINT16 RO 0x4003 16387dez 1C32 05 Minimum cyc...

Page 96: ...L cycle was not completed in time or the next cycle began too early UINT16 RO 0x0000 0dez 1C32 0D Shift too short counter Number of occasions that the interval between SYNC0 and SYNC1 event was too sh...

Page 97: ...th SM 3 Event is supported no outputs available Bit 2 3 01 DC mode is supported Bit 4 5 01 input shift through local event outputs available Bit 4 5 10 input shift with SYNC1 event no outputs availabl...

Page 98: ...bIndex 002 Analog Input Module Channel 2 UINT32 RW 0x0000012C 300dez F010 03 SubIndex 003 reserved UINT32 RW 0x00000000 0dez F010 04 SubIndex 004 reserved UINT32 RW 0x00000000 0dez F010 05 SubIndex 00...

Page 99: ...customer calibration data adjustment data used by the device during operation in order to maintain the assured measuring accuracy The terminal constantly records measured values and saves the raw val...

Page 100: ...bration offset can be activated via index 0x80n0 0A 84 0x80n0 17 84 AA User calibration gain can be activated via index 0x80n0 0A 84 0x80n0 18 84 BS User scaling offset can be activated via index 0x80...

Page 101: ...ndex 0x80n0 01 Parameterization takes place via the indices 0x80n0 11 User scaling Offset 0x80n0 12 User scaling Gain Producer Codeword Beckhoff reserves the right to implement the basic calibration o...

Page 102: ...Index 0x6010 11 Value 0x1A03 0x1A02 2 0 AI Compact Channel 2 Index 0x6010 11 Value 0x1A10 28 0 HART Cmd3 Channel 1 see note 1 Index 0x6080 01 88 Field Device Status Index 0x6080 02 Cyclic Frame Cnt In...

Page 103: ...t and cannot increase or decrease any further 0x02 Non Primary Variable Out of Limits A Device Variable not mapped to the PV is beyond its operating limits 0x01 Primary Variable Out of Limits The PV i...

Page 104: ...0 07 or 0x80n0 08 serve to activate the limit value monitoring Output limit n 2 bit 0 not active 1 Value is smaller than the limit value 2 Value is larger than the limit value 3 Value is equal to the...

Page 105: ...10 V x 216 2 1 24 247dec Output Input channel 1 Index 0x6000 03 Index 0x6000 05 1 8 V 0x01hex Limit 1 limit value undershot 0x01hex Limit 2 limit value undershot 2 8 V 0x03hex Limit 1 limit value reac...

Page 106: ...he index The terminal remains in OP mode during this process The changeover may result in longer sampling times and step changes in the process data until the filters have assumed a steady state DC mo...

Page 107: ...0x1 50 Hz FIR typi cal 625 s 60 Hz FIR typi cal 520 s IIR typical 1 ms 600 s 500 s typ data update time EL30x2 typ data update time EL30x4 typ data update time EL30x8 50 Hz FIR typ 1 25 ms 60 Hz FIR t...

Page 108: ...er or an Infinite Impulse Response filter an IIR filter The filter is deactivated by default Please observe the following note regarding activation with index 0x8000 06 84 Activation of the filter wit...

Page 109: ...in 8 levels i e cut off frequencies level 1 weak recursive filter up to level 8 strong recursive filter The IIR can be understood to be a moving average value calculation after a low pass filter Throu...

Page 110: ...16 bit are transmitted per channel Compact only the Value 16 bit is transmitted per channel The settings are described below taking the EL3102 2 channels 10V as an example The data apply to TwinCAT 2...

Page 111: ...wards Control status word Status word The status word SW is located in the input process image and is transmitted from terminal to the controller Bit SW 15 SW 14 SW 13 SW 12 SW 11 SW 10 SW 9 SW 8 Name...

Page 112: ...lies above the upper permissible threshold for this terminal SW 0 Underrange 1bin Analog input signal lies under the lower permissible threshold for this terminal from rev EL31xx 0000 0016 Control wo...

Page 113: ...16 All channels of the EL31x2 are simultaneously set to legacy legacy compact standard or compact process image Selective PDO selection All TwinCAT versions support the selective selection of individu...

Page 114: ...de for previous 2 channel 16 bit input terminals EL31x2 and should not be used for new configurations This mode ensures complication free re placement of older EL31x2 models with new ones See also the...

Page 115: ...g sizes are also offered for linking Select the corresponding 1 byte input variable for your application The 8 bit coverage is confirmed in the following SizeMismatch dialog Fig Element orientated pro...

Page 116: ...cted for unrequested or mistaken write access by a password to be entered within CoE 0xF009 CoE write access by the user PLC or start up entries in Single or CompleteAccess access Overwriting the valu...

Page 117: ...Process Industries as its major task In this role the NAMUR releases the so called NE proposed standards each numbered continuously Information with regard to the implementation of this recommendatio...

Page 118: ...a the obtained information Sets the address through which Cmd0 is polled possible range 0 63 PollingTime If a cyclic HART communication is enabled this value specifies the cycle time MaxRetrys If a HA...

Page 119: ...or packed ASCII Lower case letters are not allowed for packed ASCII If lower case letters are used they are auto matically converted to capital letters 6 3 Measured values Command 3 has a special func...

Page 120: ...additional process data which can be read by the control system can be created by ticking the Cyclic Process Data checkbox Fig 120 Additional PDO Cmd 3 of the HART communication Once the configuration...

Page 121: ...d plus the user data to be written without header and CRC The structure of the data to be used is described in the corresponding HART documentation e g Universal Command Specification If a HART comman...

Page 122: ...DT Once the terminal box has been selected in the Solution Explorer available from TwinCAT 3 1 previously System Manager in TwinCAT 2 11 the usual tabs are available in addition FDT Fig 121 FDT tab ba...

Page 123: ...ding channel of a terminal box Double click to open a further tab within FDT showing sensor actuator specific configuration windows Fig 123 General structure of a DTM configuration window within the f...

Page 124: ...Select Online to establish a bus connection with the device which opens up additional manufacturer specific functions via the context menu Fig 125 Context menu of a DTM sensor actuator offline The fun...

Page 125: ...ufacturer specific device drivers which may simplify the selection of a type conforming DTM Fig 127 Result after a DTM scan via the FDT plug in in TwinCAT 7 2 Using an external FDT application A separ...

Page 126: ...ccordingly One possible form of this application shows On the left a Project Explorer with the currently configured devices In the center the menus for the individual objects DTMs On the right the dev...

Page 127: ...Field Device Tool FDT EL3182 127 Version 1 2 Fig 130 Procedure with the FDT application for HART DTM access via the Beckhoff_ComDTM...

Page 128: ...02 2017 04 03 2017 06 04 2017 07 This is the current compatible firmware hardware version at the time of the preparing this documentation Check on the Beckhoff web page whether more up to date docume...

Page 129: ...annot be retrofitted it is a component of many new developments from year of manufacture 2016 Following the update its success should be verified ESI Revision e g by means of an online scan in TwinCAT...

Page 130: ...fer to the EtherCAT system documentation Update of XML ESI description The device revision is closely linked to the firmware and hardware used Incompatible combinations lead to malfunctions or even fi...

Page 131: ...configured In this case the configuration can be adapted with the Copy Before button The Extended Information checkbox must be set in order to display the revision Changing the ESI slave identifier Th...

Page 132: ...EtherCAT devices read a modified ESI description immediately or after startup from the INIT Some communication settings such as distributed clocks are only read during power on The Ether CAT slave the...

Page 133: ...fline The EtherCAT Slave Information ESI XML may contain the default content of the CoE This CoE directory can only be displayed if it is included in the ESI e g Beckhoff EL5xxx xml The Advanced butto...

Page 134: ...e by Beckhoff support Valid for TwinCAT 2 and 3 as EtherCAT master Switch TwinCAT system to ConfigMode FreeRun with cycle time 1 ms default in ConfigMode is 4 ms A FW Update during real time operation...

Page 135: ...Controller firmware for processing I O signals FPGA firmware for EtherCAT communication only for terminals with FPGA The firmware version number included in the terminal serial number contains both f...

Page 136: ...right click the table header and select Properties in the context menu Fig 140 Context menu Properties The Advanced Settings dialog appears where the columns to be displayed can be selected Under Dia...

Page 137: ...terminal must have FPGA firmware version 10 or higher Older firmware versions can only be updated by the manufacturer Updating an EtherCAT device The following sequence order have to be met if no othe...

Page 138: ...nager select the terminal for which the FPGA firmware is to be updated in the example Terminal 5 EL5001 and click the Advanced Settings button in the EtherCAT tab The Advanced Settings dialog appears...

Page 139: ...the device A download of firmware to an EtherCAT device must not be interrupted in any case If you interrupt this process by switching off power supply or disconnecting the Ethernet link the EtherCAT...

Page 140: ...PDO Double click on SubIndex 001 to enter the Set Value dialog Enter the value 1684107116 in field Dec or the value 0x64616F6C in field Hex and confirm with OK Fig Entering a restore value in the Set...

Page 141: ...components there Beckhoff Headquarters Beckhoff Automation GmbH Co KG Huelshorstweg 20 33415 Verl Germany Phone 49 5246 963 0 Fax 49 5246 963 198 e mail info beckhoff com Beckhoff Support Support off...

Page 142: ...herCAT State Machine 19 Fig 14 CoE Online tab 21 Fig 15 Startup list in the TwinCAT System Manager 22 Fig 16 Offline list 23 Fig 17 Online list 23 Fig 18 Spring contacts of the Beckhoff I O components...

Page 143: ...t TwinCAT 2 right TwinCAT 3 57 Fig 63 Differentiation local target system left TwinCAT 2 right TwinCAT 3 58 Fig 64 Scan Devices left TwinCAT 2 right TwinCAT 3 58 Fig 65 Note for automatic device scan...

Page 144: ...om TwinCAT 2 11 build 1544 onwards 111 Fig 113 Predefined PDO assignment in the EL3102 0000 0016 113 Fig 114 Selective PDO selection 114 Fig 115 3 byte interface of the EL31x2 115 Fig 116 Connecting t...

Page 145: ...pdate 132 Fig 136 Selecting the new ESI 132 Fig 137 Display of EL3204 firmware version 133 Fig 138 Firmware Update 134 Fig 139 FPGA firmware version definition 136 Fig 140 Context menu Properties 136...

Reviews: