SA-COM Series 

 Push-typed Screwless Terminal Block for Power Common

User’s Guide

Thank you for purchasing product of SAMWON ACT. 
Please check model of product that you purchase first, and read this manual prior to use it. 

 

Caution for Safety

  Caution

Case that results in serious damage in human body or equipment, and fire if user handles this equipment wrongly

  Warning

Case that results in slight damage in human body or equipment, and fire if user handles this equipment wrongly

  Caution

1. When machining and wiring the mounting hole, do not allow foreign matter such as dust or wire covering  
   to enter the connection terminal. Failure to do so may result in damage to the unit, heat, or ignition. 
2. Be sure to shut off the power supply from the outside before mounting and wiring. 

  Warning

1. Use within the specified temperature range. (-10

 ~ +50

) Damage to the outer case may occur. 

2. Use within the specified rated voltage and rated current range.  
   This may result in fire or damage to the product. 
3. Read this user's guide which is attached to product, and check product's nominal, characteristics,  
   specification, wiring diagram and how to handle prior to use.  
4. Please make sure to check the arrangement of the +,- when wiring. 
   It may be the cause of malfunction or damage of this equipment and user's.

 The connection cable for PLC of various makers is provided by us. Please refer to the  

    catalogue or contact Head or branch office if you need more detail models and specifications.

 

Model Selection

 

Characteristics

 Material

 Be sure to use a ferrule or round type terminal when using a stranded wire.

 

Model Configuration 

 Common dedicated Push Type 5.0mm pitch 

    

European screwless terminal block 

 No. of terminal Poles  

 Common terminal configuration

SA-COM 20

           

             

    

Model

No. of 

Poles

Common terminal configuration

Dimensions 
(W * D mm)

Mounting 

method

SA-COM20

20

Upper row 10P(+)/ Lower row 10P(-) Common

57.5 

 48.0

Screw  

mounting/ 

DIN Rail

SA-COM20B

Left side row 10P(+)/ Right side row 10P(-) Common

SA-COM20D

40(20x2)

Upper terminal block 20P(+) / Lower terminal block 20P(-) Common

63.0 

 56.2

DIN Rail

SA-COM40

40

Upper row 20P(+)/ Lower row 20P(-) Common

107.5 

 48.0

Screw  

mounting/ 

DIN Rail

SA-COM40B

Left side row 20P(+)/ Right side row 20P(-) Common

Rated voltage

125V AC / 24V DC

Rated current

10A (Total)

Insulation resistance

100

 or above (DC 500V)

Dielectric strength

AC500V 1min

Applicable 
wire

Single wire

0.5~1.5

Twisted wire

UL : 17~22AWG / IEC 1.0

Wire stripping length

8~9mm

Ambient temperature

-10

 

~

 

+50

 (No condensation)

Terminal 

PA66 

Pin header 

Copper, Tin plated 

Wire guard 

Stainless steel

Cover

Modified PPO

P.C.B

Epoxy 1.6t 

 Ferrule Selection

AWG/ (

DIN46228

Other

A(

)

B(

)

C(

)

20/0.5 

White

White/Orange

10.0

1.3

3.2

18/0.75 

Gray

Blue/White

10.0

1.5

3.4

17/1.0

Red

Red/Yellow

10.0

1.7

3.6

 Method of removal wire 

 Appropriate tool 

'ULYHU

When using a stranded wire, 
use a ferrule or a round type 
terminal. In case of a solid wire,  
use it without crimping tool.

Insert into the terminal block 
without using a separate tool.

When disconnecting the wires,  
keep the disconnect button  
pressed with the driver (- type)  
and disconnect the wires.